System requirements
Required hardware
Hardware required for clustering
The following tables list all the hardware required to convert your filers into a cluster. What you have in your individual filers determines what you should add for clustering. See the NOW Web site at http://now.netapp.com for the most current hardware requirements.
Node hardware requirements
The following table lists the minimum and maximum number of Fibre Channel adapters and cluster interconnect adapters used to cluster your filers.
Required hardware
|
Minimum configuration per node
|
Maximum configuration per node
|
Fibre Channel adapters
- FC-AL adapters
- FC-AL adapters-mirrored cluster
- Dual Fibre Channel adapters (each has a Port 1 for Channel A and a Port 2 for Channel B)
- Dual Fibre Channel adapters-synchronous mirroring for clusters
|
|
2
|
4
|
4
|
4
|
1
|
2
|
2
|
4
|
Cluster adapters:
|
1
|
1
|
Disk shelf hardware requirements
The following table lists the minimum and maximum hardware configurations for your disk shelves. See the NOW Web page at http://now.netapp.com for more information about disk shelf capacity.
Required hardware
|
Minimum
|
Maximum
|
LRCs: FC7, FC8, or FC9 disk shelves DS14 disk shelves
ESH: DS14 or DS14mk2 FC
|
4 2
2
|
48 32
32 standard and 48 for mirroring
|
Disk shelves of the same type Mix of FC7, FC8, FC9, and DS14 disk shelves
Caution FC7 disk shelves cannot use 18-GB, 36-GB, or 72-GB disks.
|
2 2
|
The number of disk shelves for both nodes must be no more than the maximum storage capacity for the nodes.
|
Cable requirements
The following table lists the minimum and maximum number of cables required for the various adapters you might have in your nodes. It also lists disk shelves requiring terminators.
Required hardware
|
Minimum
|
Maximum
|
4m cluster interconnect cables for cluster interconnect adapters
or
Optical cables for clusters separated by no more than 30 meters.
IB cluster adapter (with 2 GBICs)
VI cluster adapter
or
SC-SC Duplex 50/125 plenum cable for VI cluster adapters separated by more then 30 meters and less than 500 meters.
|
2
|
2
|
2 (SC/SC)
1 (LC/LC)
|
2
1
|
Optical cables for dual Fibre Channel adapters
2m filer-to-shelf (HSSDC to DB-9) cables for FC-AL adapters
Note If your cluster is separated by more than 30 meters, you must use a SC-SC Duplex 50/125 plenum cable to connect the disk shelves from the local node to partner's disk shelves and vice-versa. |
4
|
8
|
4
|
8
|
0.5m shelf-to-shelf (DB-9 to DB-9) cables for DS14 disk shelves
or
LC-SC or LC-LC cables
|
2
|
You need 2(n - l) number of cables, where n is the number of disk shelves and l is the number of loops.
|
Terminators for FC7 and FC8 disk shelves only
|
2
|
4
|
Copyright © 1994-2003, Network Appliance, Inc. All rights
reserved.
Part No. 210-00341
File: ch2conv3.htm