To prepare your new disk shelf for addition to your existing cluster, complete the following steps.
Step
|
Action
|
|
1 |
Disable negotiated failover in your cluster by entering the following command from the node console:
cf nfo disable disk_shelf
|
|
2 |
Install the new disk shelf in your equipment rack, as described in the DiskShelf14 and DiskShelf14mk2 FC Hardware Guide.
|
|
3 |
Ground the new disk shelf, then give the disk shelf a unique shelf ID.
|
|
4 |
Verify that the new disk shelf ID is unique by entering the following command:
fcstat device_map
Result
Shelf ID's for all Fibre Channel devices are listed.
|
|
5 |
If disk shelves in the loop to which you are adding the new disk shelf have...
|
Then, for loops with...
|
LRCs
|
|
ESHs
|
|
|
6 |
Plug in the new disk shelf and turn it on.
|
|
7 |