Library Table of Contents Index Previous Next Comments

Cabling a new Fabric Attached MetroCluster

Step 2: Configuring the local switches

Tasks for configuring the switch  Top

To configure the Brocade 3800 or 3200 switch for clustering, complete the following steps.

Note
Check the NOW site at http://now.netapp.com/NOW to confirm the following procedure.

Step

Action

1

Log in to the switch, using the console port and hyperterm, and set the appropriate variables and IP addresses, as described in the appropriate Brocade switch hardware reference manual.

Note
Use telnet for subsequent switch login sessions, using the switch IP address.

2

Check the switch firmware by entering the following command:

version
Result

The currently installed switch firmware is displayed. See the NOW Web site at http://now.netapp.com/NOW for the current version of switch firmware.

3

If the switch firmware is...

Then...

Current

Go to Step 4.

Out of date

  1. Download the switch firmware from the NOW Web site at http://now.netapp.com/NOW and install it, as described in the appropriate Brocade switch hardware reference manual.
  2. Reboot the switch.
4

Disable the switch by entering the following command:

switchdisable
5

Clear any existing configuration on the switch by entering the following command:

cfgclear
6

Ensure that the switch is configured with default settings by entering the following command:

configdefault
7

Set the switch parameters by entering the following command:

configure
Result

You should only set the following parameters:

  • Fabric parameters = y
  • domain_id = XXX (See your system administrator for this value.)
  • Disable device probing = 1
8

Exit the configuration utility by entering the following command:

ctrl-d
9

Reboot the switch so that the default settings take effect by entering the following command:

fastboot
10

Log in to the switch and disable the switch by entering the following command:

switchdisable
11

Set the switch port speeds to half duplex by entering the following command for each switch port into which a disk is plugged:

portcfglport port# 0,0,1 

Note
You only need to do this command on the ports to which disks are attached.

12

If the distance between switches is...

Then...

Between 500 meters and 10 kilometers

Set the ISL port distance on each ISL port to short distance by entering the following command:

portCfgLongDistance ISL-port#, LE

Between 10 and 30 kilometers

Set the ISL port distance on each ISL port to long distance by entering the following command:

portCfgLongDistance ISL-port#, L1

13

Save the new switch configuration by entering the following command:

cfgsave
14

Enable the switch by entering the following command:

switchenable
15

Set the switch name by entering the following command:

switchname Metro1_switch1

Metro1_switch1 is the name you gave to the current switch. Use a name that is meaningful, such as node name and switch, as in the previous example.

16

Check the switch settings by entering the following command:

configshow
17

Repeat Steps 1 through 16 on the second switch on the local node.

18

Go to Step 3: Cabling the local node

Library Table of Contents Index Previous Next Comments