To close the F85, complete the following steps.
Step
|
Action
|
|
1 |
Check all cable connections, especially those that might have come loose during your work. Fold cables out of the way so that they do not catch on the computer cover.
|
|
2 |
Check that no tools or parts (including screws) are left inside the computer.
|
|
3 |
Fit the side cover over the side rail at the bottom of the chassis, and slide it closed.
|
|
4 |
Secure the cover with the three thumbscrews.
|
|
5 |
Repeat Steps 3 and 4 to reinstall the remaining side cover, if necessary.
|
|
6 |
Snap the two tabs near the lower inside edge of the front bezel into the corresponding metal clips on the chassis, and pivot the bezel upward into its closed position.
|
|
7 |
Turn the keylock on the front bezel of the computer to the locked position.
|
|
8 |
If you had removed your F85 from a rack, reinstall it in the rack.
|
|
9 |
If the unit you replaced is...
|
Then...
|
Not the SCSI backplane, the motherboard, or the motherboard lithium battery
|
- Insert the NetApp
Diagnostics diskette into the
F85 diskette drive.
- Go to Step 10.
|
|
The SCSI backplane
|
- Insert the Utility diskette
that came with your unit
into the F85 diskette drive.
- Turn on the F85.
- When asked, press F1 to
continue.
- Select the following option:
Update ESM and System
Backplane
- Exit the Utility when you
have completed the updates.
- Remove the Utility diskette.
- Insert the NetApp
Diagnostics diskette into the
F85 diskette drive.
- Go to Step 10.
|
|
The motherboard or the motherboard lithium battery
|
- Insert the Utility diskette
that came with your unit
into the diskette drive.
- Turn on the F85.
- When asked, press F1 to
continue.
- Select the following option:
Change Service Tag
- Select the following option:
Update ESM and System
Backplane
- Select the following option
and make a note of the
information:
Display MAC address
Note You need the MAC address for network configuration.
- Exit the Utility after you
complete the updates.
- Remove the Utility diskette.
- Insert the NetApp
Diagnostics diskette into the
F85 diskette drive.
- Go to Step 10.
|
|
10 |
Reboot the system to boot the diagnostics program.
After the booting process, the Diagnostics Monitor appears listing all available features.
|
|
11 |
Run the specific diagnostics that apply to the unit that you installed or replaced.
Note Some field replacement units have do not have specific diagnostics tests. |