Library Table of Contents Index Previous Next Comments

Installing an R150 disk shelf

Disk shelf fundamentals

Supported disk drives  Top

Each R150 disk shelf supports twelve 250-GB ATA hard disk drives with an actual storage capacity of 212 GB per hard drive after formatting.

Disk drive labeling  Top

Each disk drive is labeled with a unique SCSI address, which helps define its location within the disk shelf. Addresses are assigned to each drive bay beginning right to left in four groups, corresponding to the disks supported by each bridge in the disk shelf.

SCSI address

Drive bay number

Bridge 1

0

0

1

1

2

2

3

3

4

SES device

reserved

5

unused

6

unused

7

SCSI adapter

Bridge 2

8

4

9

5

10

6

11

7

Bridge 3

12

8

13

9

14

10

15

11

Therefore, the 12 drive bays in the disk shelf are labeled between 0 and 15 from right to left with SCSI addresses 4, 5, 6, and 7 reserved for other internal functions. The SCSI address labels are shown in the following illustration.

Enclosure services monitoring  Top

The R150 uses the enclosure services monitoring method to monitor environmental conditions of the disk shelf. Enclosure services conditions are communicated to the storage engine through the EMU module.

The following table describes the four stages of enclosure services monitoring.

Stage

Device

What it does...

1

Storage engine

Uses a subset of SCSI-3 commands to monitor the disk shelf for data related to disk presence, temperature, power supply units, and fan status.

2

Disk shelf

The SCSI-ATA bridge requests information from the EMU.

3

Disk shelf

The EMU returns the environmental data to the bridge.

4

Disk shelf

The bridge returns EMU data to the storage engine.

Library Table of Contents Index Previous Next Comments