Replacing fan subassemblies
About replacing fan subassemblies
Replacing a fan subassembly consists of the following procedures:
Identifying the subassembly to replace
Each of the three fan subassemblies secured to the front of the storage engine chassis contains two fans. If a problem occurs in a fan, the system console displays an error message identifying the specific fan that has the problem, rather than the subassembly it belongs to.
Note
You cannot replace the individual fan; you must replace the subassembly.
The following table lists the individual fan numbers that the console might display and their corresponding subassemblies.
Fan number (as indicated on your console)
|
Subassembly (as indicated on your chassis)
|
Baseboard fan 1
|
Subassembly 1
|
Baseboard fan 2
|
Baseboard fan 3
|
Subassembly 2
|
Baseboard fan 4
|
Baseboard fan 5
|
Subassembly 3
|
Baseboard fan 6
|
Note
To maintain UL, CSA, and TUV safety certifications, you must obtain replacement fan subassemblies from Network Appliance. Using unapproved replacement fan subassemblies voids the safety certifications.
Removing a fan subassembly
To remove a fan subassembly, complete the following steps.
Note
Because the three subassemblies are hot swappable, there is no need to shut down the storage engine. There is a two-minute window for replacing fans.
Step
|
Action
|
|
1 |
From the console, note the identification of the fan that failed and identify the subassembly that it belongs to.
|
|
2 |
Pull the bezel straight off the front panel of your appliance by using the grooves on the left and right edges of the bezel.
|
|
3 |
Using a #1 Phillips screwdriver, loosen the thumbscrews on the chassis fan subassembly that failed.
|
|
4 |
Using both the upper and lower lips, pull the subassembly out of the storage engine chassis. The sheet metal below the subassemblies is silk-screened with the labels Fan 1, Fan 2, and Fan 3.
Note If your appliance is running Data ONTAPTM software, it reports a failure for the removed fan subassembly.
|
|
5 |
Set the subassembly aside.
|
Installing a fan subassembly
To install a fan subassembly, complete the following steps.
Step
|
Action
|
|
1 |
Slide the subassembly straight into the storage engine chassis.
|
|
2 |
Tighten the subassembly thumbscrews.
|
|
3 |
Align the pins on the bezel with the holes on the front panel of the storage engine, then push the bezel straight onto the front panel.
|
|
4 |
Reconnect and turn on the power to the storage engine.
|
|
5 |
Interrupt the boot process by pressing the Delete key during the memory test.
|
|
6 |
Run diagnostics by entering the following command at the ok> prompt:
sys-diag
See the Diagnostics Guide for more information.
|
|
7 |
Run the diagnostics that apply to the unit you installed or replaced.
|