These error messages might appear on the system console or LCD when the system is operating, when it is halted, or when it is restarting because of system problems.
The following table describes other error messages that might appear on the LCD if your storage engine encounters errors while starting up or during operation.
The following table describes other error messages that might appear on the console if your storage engine encounters AT-FC module errors while starting up or during operation. The output displayed on the console is similar to the following example.
Wed Aug 6 19:31:40 PDT [scsi.cmd.notReadyCondition:notice]: Device 11b.44: Device returns not yet ready: CDB 0x41:026d0880:5000: Sense Data SCSI:not ready - (0x2 - 0x4 0x7 0x0)(28615).
00h |
00h |
00h |
No sense |
|
01h |
5Dh |
20h |
Recovered error, controller impending error, general hard drive failure, SMART notification. |
Notification was sent out and follow-on log messages identify and clarify corrective action. |
02h |
04h |
00h |
Not ready, cause not reportable (drive failed to spin-up and become ready). |
|
02h |
04h |
01h |
Not ready, logical unit is in the process of becoming ready (drive spinning up). |
|
02h |
04h |
03h |
Logical unit not ready, manual intervention required (drive failed to become ready after error recovery or drive not installed). |
Replace or install a disk drive in the identified location, as described in Replacing a disk in a disk shelf. |
02h |
04h |
07h |
Logical unit not ready, command in progress (drive command timeout). |
|
03h |
11h |
00h |
Media error, unrecoverable read error (ATA UNC). |
|
03h |
12h |
00h |
Media error, address mark not found for ID (ATA AMNF, drive vendor unique) |
|
03h |
14h |
01h |
Medium error, record not found. (ATA IDNF) |
|
03h |
15h |
01h |
Medium error, mechanical positioning error (ATA TRK0 NF, drive vendor unique). |
|
04h |
44h |
00h |
Hardware error, internal target failure (ATA FW PROB, drive vendor unique or unrecognized ATA error). |
|
05h |
20h |
00h |
Illegal request, invalid command Op Code. |
|
05h |
21h |
00h |
Illegal request, logical block address out of range. |
|
05h |
24h |
00h |
Illegal request, invalid field in CDB. |
|
05h |
26h |
00h |
Illegal request, invalid field in parameter list. |
|
06h |
29h |
00h |
Unit attention, reset or target reset occurred. |
|
06h |
29h |
01h |
Unit attention, power-on occurred. |
|
06h |
3Fh |
03h |
Unit attention, inquiry data changed. |
|
0Bh |
08h |
03h |
Hardware error, logical unit communication error (ATA ICRC). |
Check the connections to ensure that they are secure and tight. If the error persists, change the cables. |
0Bh |
44h |
00h |
Aborted command, internal target failure (ATA ABRT). |
The following error messages appear on the storage appliance console if an SES element on the AT-FC module fails. See Replacing the AT-FC module for more information. The output displayed on the console is similar to the following example.
Mon Aug 25 21:34:05 GMT [ses.status.temperatureWarning:warning]: DS14-Mk2-AT shelf 3 on channel 5a temperature warning for Temperature sensor 1: non-critical status; undertemperature warning. Current temperature: 1 C (33 F). This module is on the front side of the shelf, at the right, on the OPS panel.
Temperature sensor 2: failed |
|
Temperature sensor 3: failed |
|
SES electronics Element 1: component is from a different product family |
This configuration is unsupported. Contact Network Appliance Customer Support. |
SES electronics Element 1: failed |
|
SES electronics Element 2: failed |
The AT-FC module on the disk shelf failed. Replace the AT-FC module, as described in Replacing the AT-FC module. |
Temperature sensor 2: not installed or failed |
|
Environmental sensor 3: not installed or failed |
|
SES electronics Element 1: not installed or failed |
|
Vendor-specific Element 1: not installed or failed |
|
SES electronics Element 2: not installed or failed |
Communication with the temperature sensor on the AT-FC module failed. Replace the AT-FC module, as described in Replacing the AT-FC module. |
Vendor-specific Element 2: not installed or failed |
The following table lists the disk shelf error messages from the front panel and the power supplies, that might be displayed on the console if you encounter disk shelf errors during start or operation.
Temperature sensor 1: failed |
The temperature sensor on the front operation panel failed. Replace the disk shelf, as described in Replacing a disk shelf in a rack. |
Alarm Element 1: failed |
The alarm on the front operation panel failed. Replace the disk shelf, as described in Replacing a disk shelf in a rack. |
Display Element 1: failed |
The display element on the front operation panel failed. Replace the disk shelves, as described in Replacing a disk shelf in a rack. |
Power supply 1: failed |
The power supply on the left back of the disk shelf failed. Replace the power supply, as described in Replacing a power supply in a disk shelf. |
Power supply 2: failed |
The power supply on the right back of the disk shelf failed. Replace the power supply, as described in Replacing a power supply in a disk shelf. |
Cooling element Element 1: failed |
The fan module on the left back power supply failed. Replace the power supply, as described in Replacing a power supply in a disk shelf. |
Cooling element Element 2: failed |
The fan module on the right back power supply failed. Replace the power supply, as described in Replacing a power supply in a disk shelf. |
Copyright © 1994-2003, Network Appliance, Inc. All rights