When you add disks to a filer, you need to insert them in a disk shelf according to the disk shelf manufacturer's instructions. They then become hot spare disks. You also add the disks to a volume with the vol add command.
You can use disks of various sizes in a volume according to the following rules:
You add disks when
Network Appliance recommends adding RAID groups and/or disks before the file system is 80% to 90% full.
The number of disks and RAID groups at initial filer configuration affects read and write performance. A greater number of disks means a greater number of independently seeking disk-drive heads reading data. Write performance can also benefit from more disks; however, the difference can be masked by the effect of NVRAM and the manner in which WAFL manages write operations.
Network Appliance recommends adding disks in multiples of 8 to 14 for overall improved performance. However, as more disks are configured, the performance increase levels off. Performance is affected more with the fewer disks you add until the striping across all the disks levels out. When the striping levels out, there is an increase in operations per second and a reduced response time.
The ideal time to add more disks to meet future storage requirements is before the applied load places stress on the existing array of disks, even though adding more disks at this time will not significantly improve the filer's current performance.
You should periodically check the number of hot spares you have on your filer and add disks if you have fewer than one per shelf. If there are no hot spare disks, you should add disks to disk shelves so they become available as hot spares.
For more information, see Hot spare disks.
To ascertain how many hot spare disks you have on your filer, complete the following step.
You add disks to a volume according to the following rules:
If an added disk is larger than an existing parity disk, the added disk replaces the smaller disk as the parity disk, and the smaller disk becomes a data disk. This enforces a Data ONTAP rule that the parity disk must be at least as large as the largest data disk in a RAID group.
Note
In volumes configured with RAID DP (which uses RAID groups that contain both a regular parity disk and a double, or dParity, disk) the larger added disk replaces any smaller regular parity disk, but its capacity will be downsized, if necessary, to avoid exceeding the capacity of any smaller-sized the dParity disk.
To add new disks to the filer, complete the following steps.
Note
In the following procedure, the NearStore R100 appliance and the original-capacity R150 appliance use disks on SCSI-attached shelves. The R150 appliance with upgraded 24 TB capacity and the R200 appliance use disks on Fibre-Channel-attached shelves.
| 1 | ||
|
Fibre Channel disks or on Fibre-Channel-attached shelves |
Go to Step 2. |
|
|
SCSI disks or on SCSI-attached shelves |
Enter the following command, and go to Step 2: disk swap |
|
| 2 | Install one or more disks according to the hardware guide for your disk shelf. Note ResultThe system displays a message confirming that one or more disks were installed and then waits 15 seconds as the disks are recognized. The system recognizes the disks as hot spare disks. Note |
|
| 3 | Verify that the disks were added by entering the following command: vol status -s ResultThe number of hot spare disks in the RAID Disk column under Spare Disks increases by the number of disks you installed. |
|
To add new disks to a volume, complete the following steps.
Note
When adding disks to a volume, Data ONTAP attempts to distribute I/O loads, such as alternating host adapters, to improve reconstruction performance. You can override this behavior by specifying the disks you want.
If a volume has more than one RAID group, you can specify the RAID group to which you are adding disks. To add new disks to a specific RAID group of a volume, complete the following step.
Note
The number of disks you can add to a specific RAID group is limited by the raidsize setting of the volume to which that group belongs. See Chapter 4, RAID Group Management for more information.
The following are situations that would fail if you tried to add disks to a volume:
To force Data ONTAP to add disks in these situations, complete the following step.
| 1 |
vol add vol-name -f [-g raidgroup] -d disk-name... Note |
Copyright © 1994-2003, Network Appliance, Inc. All rights
reserved.
Part No. 210-00472
File: disks7.htm
Last updated: 11/17/03 16:57:35