This section describes how the filer reacts to a disk failure when hot spare disks are not available.
If a disk fails, the filer continues to run without losing any data but performance is somewhat degraded. (If RAID DP is enabled, the filer can continue running with one or two disks failed in a RAID group.)
Caution
Replace the failed disks as soon as possible, because additional disk failure might cause the filer to lose the entire file system.
The filer logs a warning message in the /etc/messages file on the root volume every hour after a disk fails.
To ensure that you notice the failure, the filer automatically shuts itself off in 24 hours, by default, or at the end of a period that you set with the raid.timeout option of the options command. You can restart the filer without fixing the disk, but it continues to shut itself off periodically until you repair the problem.
Check the /etc/messages file on the root volume once a day for important messages. You can automate checking of this file from a remote host with a script that periodically searches the file and then alerts you.
Alternatively, you can monitor Autosupport messages. Data ONTAP sends Autosupport messages when a disk fails.
After you replace a disk, the filer detects the new disk immediately and uses it. The filer starts file service and reconstructs the missing data in the background to minimize service interruption.
Copyright © 1994-2003, Network Appliance, Inc. All rights
reserved.
Part No. 210-00472
File: raid6.htm