Understanding traps in Data ONTAP

About traps  Top

Traps are mechanisms that alert you to significant events on the filer. If SNMP is configured, traps are fired when a defined event, such as a network traffic interruption or line power failure, occurs. Trap information, in the form of MIB Object Identifiers (OIDs), is sent from the filer agent to an SNMP management station.

About built-in traps in Network Appliance MIBs  Top

Built-in traps in Network Appliance MIBs are identified by the string TRAP-TYPE. For example, the following is a complete trap definition from the Network Appliance custom MIB:


upsLinePowerOff TRAP-TYPE
ENTERPRISE              netapp
DESCRIPTION
     "UPS: Input line power has failed and UPS is now on battery."

 
::= 142

Traps in the Network Appliance custom MIB are provided in a number of categories, including the following:

Category

Examples of trap messages

Disk Health Monitor

Degraded I/O, disk predictive-failure event

Disks

Disk - failure alert, shutdown, repaired

Fan

Fan - failed, shutdown, warning, repaired

Power supply

Power supply - failed, shutdown, warning, repaired

CPU

CPU busy, OK

NVRAM

Battery discharged, low

Cluster

Node failed, repaired

Volumes

Nearly full, full, repaired

Temperature

Over temperature, shutdown, repaired

Shelf

Fault, repaired

Global

Not recoverable, critical, not critical, OK

Soft quotas

Exceeded, normal

Autosupport

Send error, configuration error, successful send

Note
These categories are examples of the MIB trap contents; it is not an exhaustive list. The most complete listings are provided in the MIBs themselves.

About MIB trap priority  Top

By convention, the right-most digit of a trap ID number indicates its priority (degree of severity), using the same enumeration as syslog entries. For example, trap ID 142 upsLinePowerOff is priority 2, alert.

Trap priorities are listed in the following table.

Trap ID last digit

Priority

1

emergency

2

alert

3

critical

4

error

5

warning

6

notification

7

information

8

debug

For more information, see the NetApp syslog.conf(5) manual page.

Where to get further information  Top

See the following RFCs for more information:

Library Table of Contents Index Previous Page (Alt-p) Next Page (Alt-n) Comments