The F825 and F880 filers and FAS900 series filers use a CompactFlash card for firmware and system software downloads.
Before initiating the standard upgrade procedure, verify that you have completed any prerequisite procedures described in Preparing for the upgrade.
To download Data ONTAP to an F825 and F880 cluster, or a FAS900 series cluster using the standard upgrade procedure, complete the following steps at the filer console.
| 1 |
Disable the cluster by entering the following command at the console of one of the filers: cf disable |
|
| 2 |
Enter the following command to copy the executables to the boot blocks of the filer's hard disks: download ResultThe download command provides an acknowledgment similar to the following: Tue Jun 19 10:03:22 GMT [download.request:notice]: Operator requested download initiated download: Downloading boot device......... download: Downloading disks: opening Data ONTAP 6.5.2 .......................done download: boot blocks successfully copied to disk(s) Then a message similar to the following appears: Tues Jun 19 10:11:51 GMT [download.requestDone:notice]: Operator requested download completed |
|
| 3 |
Enter the following commands to compare the installed version of system firmware with the version on the CompactFlash card: sysconfig -a version -b ResultThe sysconfig command output contains an entry similar to the following: Firmware release: 4.2_i1 The version command output contains an entry similar to the following: 1:/x86/firmware/xfiler/firmware.img: Firmware 4.2.2_i2 If the version of the newly loaded firmware displayed by the version command is
|
|
| 4 |
Enter the following command to shut down the filer: halt Result |
|
| 5 |
bye |
|
| 6 |
During the memory test, press Del to interrupt the boot process. Note ResultThe console displays the following messages: Skipping auto-boot Complete Startup aborted |
|
| 7 | ||
|
Go to Step 8. | ||
|
Go to Step 10. | ||
| 8 |
update-flash Result |
|
| 9 |
ResultThe system updates the firmware, displays several status messages, and displays the ok prompt. Note |
|
| 10 |
Enter the following command to reboot the system using the new firmware and software: bye |
|
| 11 |
While the cluster is disabled, repeat Step 2 through Step 10 at the filer console of the partner filer. Caution |
|
| 12 | ||
|
Reenable the cluster by entering the following command on one of the filers: cf enable | ||
|
Wait for the console to display the Troika firmware download complete and Resetting Troika NIC messages. Then reenable the cluster by entering the following command on one of the filers: cf enable | ||
| 13 |
Update the disk firmware by entering the following command first at the console of one of the clustered filers and then at the console of the partner filer: disk_fw_update |
|
| 14 |
As needed, perform the procedures described in Concluding the upgrade. |
|
FAS270 filers use a CompactFlash card for firmware and system software downloads.
Before initiating the standard upgrade procedure, verify that you have completed any prerequisite procedures described in Preparing for the upgrade.
To download Data ONTAP to clustered FAS270 filers using the standard upgrade procedure, complete the following steps at the console of one of the filers in the cluster.
| 1 |
Disable the cluster by entering the following command at the console of one of the filers: cf disable |
|
| 2 |
Enter the following command to copy the executables to the boot blocks of the filer's hard disks: download ResultThe download command provides a status message similar to the following: download: Depending on system load, it may take many download: minutes to complete this operation. Until it download: finishes, you will not be able to use the download: console. You can cancel this operation by download: hitting Ctrl-C in the next 6 seconds. Tue Jul 15 10:03:22 GMT [download.request:notice]: Operator requested download initiated download: Downloading boot device......... download: Downloading boot device (Service Area) Then the following filer message appears: Tues Jul 15 10:11:51 GMT [download.requestDone:notice]: Operator requested download complete |
|
| 3 |
Enter the following commands to compare the installed version of system firmware with the version on the CompactFlash card: sysconfig -a version -b ResultThe sysconfig command output contains an entry similar to the following: Firmware release: CFE 1.1.0 The version command output contains an entry similar to the following: 1:/mips/firmware/fas270/firmware.img: Firmware 1.1.0 If the version of the newly loaded firmware displayed by the version command is
|
|
| 4 |
Enter the following command to shut down the filer: halt ResultAfter the filer shuts down, the CFE firmware prompt appears. Note |
|
| 5 | ||
|
Go to Step 6. | ||
|
Go to Step 8. | ||
| 6 |
At the CFE prompt, enter the following command: update_flash ResultThe update_flash command provides an acknowledgement similar to the following. Reading flash0a: Done. 493328 bytes read ** DO NOT TURN OFF YOUR MACHINE UNTIL THE FLASH UPDATE COMPLETES!! ** Programming...done. 493328 bytes written Reading fatfs://ide0.0/MIPS/firmware/FAS250/firmware.img: Done. 493392 bytes read Flash image is 493328 bytes, flags 00000002, CRC DE227E0D ** DO NOT TURN OFF YOUR MACHINE UNTIL THE FLASH UPDATE COMPLETES!! ** Programming...done. 493328 bytes written |
|
| 7 |
ResultThe system updates the firmware, displays several status messages, and displays the CFE prompt. |
|
| 8 |
At the CFE prompt, enter the following command to reboot the system using the new software and, if applicable, the new firmware: bye |
|
| 9 |
While the cluster is disabled, repeat Step 4 through Step 8 at the filer console of the partner filer. Caution |
|
| 10 |
Reenable the cluster by entering the following command on one of the filers: cf enable |
|
| 11 |
Update the disk firmware by entering the following command first at the console of one of the clustered filers and then at the console of the partner filer: disk_fw_update |
|
| 12 |
As needed, perform the procedures described in Concluding the upgrade. |
|
Before initiating the standard upgrade procedure, verify that you have completed any prerequisite procedures described in Preparing for the upgrade.
To download Data ONTAP to clustered F810, F820, or F840 filers, or to clustered F700 series filers using the standard upgrade procedure, complete the following steps at the console of one of the filers in the cluster.
| 1 |
Disable the cluster by entering the following command: cf disable |
|
| 2 |
Enter the following command to copy the executables to the boot blocks of the filer's hard disks: download ResultThe download command provides a status message similar to the following: Tue Jun 19 10:03:22 GMT [download.request:notice]: Operator requested download initiated download: Downloading disks: opening Data ONTAP 6.5.2 .......................done download: boot blocks successfully copied to disk(s) Then a message similar to the following appears: Tues Jun 19 10:11:51 GMT [download.requestDone:notice]: Operator requested download completed |
|
| 3 |
Reboot the filer with the following command: reboot |
|
| 4 |
While the cluster is disabled, repeat Step 2 and Step 3 on the partner filer. Caution |
|
| 5 | ||
|
Reenable the cluster by entering the following command on one of the filers: cf enable | ||
|
Wait for the console to display the Troika firmware download complete and Resetting Troika NIC messages. Then reenable the cluster by entering the following command on one of the filers: cf enable | ||
| 6 | ||
| 7 |
As needed, perform the procedures described in Concluding the upgrade. |
|
Copyright © 1994-2004, Network Appliance, Inc. All rights
reserved.
Part No. 215-01027
File: ug_sw11.htm
Last updated: Mon Jul 12 17:06:07 2004