Removing the CPU module

Reasons for removing the CPU module  Top

There are several reasons for removing the CPU module:

Removing the CPU module  Top

To remove the CPU module, complete the following steps.

Step

Actions

1

If you are performing...

Then...

A planned CPU module replacement on a clustered GF270c

Determine which module is to be replaced. From the partner CPU module, perform a takeover operation by entering the following command:

cf takeover

An unplanned CPU module replacement on a clustered GF270c, where the partner node performed a takeover

Proceed to Step 2.

An unplanned CPU module replacement on a clustered GF270c, where the partner node did not perform a takeover

Proceed to Step 2.

2

Put on the antistatic wrist strap and attach the grounding leash to the gateway chassis.

3

Disconnect all cables to the CPU module that you are replacing.

4

At the rear-center of your gateway, using your thumb and index finger of both hands, press the cam mechanism levers in the middle of the CPU module to release it.

The following figure shows how to release the cam mechanism.

5

Carefully pull the cam handle so that the CPU module slides out from the chassis. The CPU module has a travel distance of approximately 10 inches (25.4 centimeters).

6

If you are...

Then...

Replacing a defective CPU module with a new one

Proceed to Moving the Data ONTAP software.

Servicing a component on the CPU module

See the appropriate procedure in this chapter. Then proceed to Replacing the CPU module.

Moving the Data ONTAP software  Top

The Data ONTAP software is installed on the CompactFlash card of the old CPU module. The CompactFlash card on the replacement CPU module is blank. To get the correct version of Data ONTAP onto the replacement CPU module, you need to move the CompactFlash card from the old CPU module to the replacement CPU module.

To install the correct version of Data ONTAP onto the replacement CPU module, complete the following steps.

Step

Action

1

Put on the antistatic wrist strap and grounding leash.

2

On the bottom side of the old CPU module, remove the CompactFlash card. Use your thumb to apply pressure to the exposed surface of the card, while gently sliding the card out of the socket.

3

Repeat the same procedure by removing the CompactFlash card from the replacement CPU module.

4

Install the old CompactFlash card into the replacement CPU module by orienting the card so that the pin slots on the card engage properly with the pins inside the socket, and then gently sliding the card into place until it is firmly seated in the socket.

Caution
Damage to the card socket and card can result if you do not orient the card properly during insertion.

5

Install the blank CompactFlash card from the replacement CPU module into the old CPU module and return the old CPU module to NetApp.

6

Proceed to Replacing the CPU module to install your replacement CPU module.