There are three separate cases to consider when installing a CPU module. Choose one of the following three procedures, based on your system criteria:
To install the CPU module in a clustered system where the partner node has not performed a takeover, complete the following steps.
| 1 |
Put on the antistatic wrist strap and grounding leash. |
|
| 2 |
Connect all cables to the CPU module before inserting the module into its CPU module bay. For more information, see the gFiler Gateway Hardware Installation Guide. |
|
| 3 |
From the back of your gateway, slide the module into the CPU module bay and push the cam mechanism levers into place. |
|
| 4 |
Set the terminate switch on the CPU module to the proper position. |
|
| 5 |
If power was removed, reconnect the power to your gateway and turn on the power switch on both power supplies. See the gFiler Gateway Hardware Installation Guide. |
|
| 6 |
If you installed a new CPU module with a new CompactFlash card, the card might not contain any data, in which case you need to boot your gateway from a remote image. See Netboot process for the GF270c. |
|
| 7 | ||
| 8 |
Run diagnostics on the new CPU module by entering the following command: |
|
| 9 |
At the diagnostics prompt, run all tests by entering the following command: |
|
| 10 |
Exit diagnostics by entering the following command: exit See the Diagnostics Guide at http://now.netapp.com for more information. |
|
| 11 | ||
| 12 | ||
| 13 | ||
| 14 |
To see all disks and the old CPU module name, enter the following command: |
|
| 15 | ||
| 16 |
Shut down the gateway by entering the following command at the console: |
|
| 17 | ||
To install the CPU module in a clustered system where the partner node has performed a takeover, complete the following steps.
| 1 |
Put on the antistatic wrist strap and grounding leash. |
|
| 2 |
Connect all cables to the CPU module before inserting it into the module bay. For more information, see the gFiler Gateway Hardware Installation Guide. |
|
| 3 |
Set the terminate switch on the CPU module to the proper position. |
|
| 4 |
From the back of your gateway, slide the module into the module bay and push the cam mechanism levers into place. |
|
| 5 |
If you installed a new CPU module with a new CompactFlash card, the card might not contain any data, in which case you need to boot your gateway from a remote image. See Netboot process for the GF270c. |
|
| 6 |
Capture the output from the console. Be sure to write down the system ID number, as shown in boldface in the following example. The output should look something like this:
Loading: 0xffffffff80001000/8500653 Entry at 0xffffffff80001000 Check that disks have been assigned ownership to this |
|
| 7 | ||
| 8 |
Reassign disk ownership for the new CPU module from the partner node with the new SYSID, by entering the following commands at the takeover prompt: |
|
| 9 |
Enter the following command using the recorded System ID from Step 6, for example: The console screen should display something resembling the following:
node x(takeover)> priv set advanced
|
|
| 10 | ||
| 11 |
Verify disk ownership. Make sure that all disks that were supposed to be reassigned, were reassigned. |
|
| 12 |
The new CPU module should see the disk on the next reboot, accompanied by the following message: From the partner node, enter the following command: Note |
|