Storage subsystem restrictions
Restrictions for all storage subsystems
The following restriction applies to the 9900V series:
- Maximum number of LUNs allowed for each channel adapter port or host group-256.
Restrictions for the 9570V/9580V/9585V storage subsystem
The following restrictions apply to the 9570V/9580V/9585V storage subsystem:
- LUN mapping--NetApp recommends that you enable LUN mapping for all configurations on your 9570V/9580V/9585V.
- LUN formatting--Do not reboot your gateway while a LUN is formatting on the 9570V/9580V/9585V.
- Data sharing--You must use the data sharing mode when your gateway is attached to the 9570V/9580V/9585V.
- LUN security--You can use LUN management software to impose security in switch-attached configurations.
- Shutting down the 9570/9580V/9585V--You must power down the gateway before shutting down the 9570/9580V/9585V.
- No RSV_Conf mode-No RSV Conf mode must be enabled for connection to the 9570V/9580V/9585V.
Restrictions for the 9900 series storage subsystems
The following restriction applies to the 9900 series storage subsystems:
- System mode 254 must be set to "on" for connection to 9900 storage subsystems.