Library Table of Contents Index Previous Page (Alt-p) Next Page (Alt-n) Comments

Terms

Array group  Top

On the storage subsystem, the arrangement of disks in the back-end that together form the defined RAID level.

Channel adapter (CHA)  Top

Includes the Client-Host Interface Processor (CHIP). The interface between the system and hosts or servers on an open system.

Cluster  Top

Two gFiler gateways directly connected to each other. This type of deployment provides redundancy in case one gFiler in the cluster becomes unavailable. Each of the gFiler gateways in the cluster might be referred to as a node--a local node or a partner node.

coredump  Top

Information written to disk to help with troubleshooting when a system failure occurs.

gFiler neighborhood  Top

The number of nodes that can see each others' LUNs. When you configure LUNs on the storage subsystem, you identify the hosts in particular neighborhoods.

LDEV  Top

Logical Device: Unit of capacity, defined at format time, that is used as capacity placeholder until it is mapped as a LUN.

LUN  Top

Logical Unit Number (LUN). An area on the storage subsystem that is available for a gFiler or non-gFiler host to read data from or write data to.

Mapping of port definitions  Top

The task of assigned LDEVs, by address, to Fibre Channel ports.

Node  Top

In a gFiler cluster, either the local or partner gFiler.

Parity group  Top

A mode of disk operation and configuration. It is synonymous with the term RAID group.

port  Top

The number of supported ports on an XP storage subsystem is dependent upon the number of supported I/O slots and the number of ports available per I/O adapter. The XP family of storage subsystems supports SCSI, Fibre Channel (FC/AL), and ESCON I/O interfaces. I/O support might vary among XP storage subsystems. Ports are named based on their port group and port letter. Examples of port names include CL1-A through CL1-R and CL2-A through CL2-R (letters I and O are skipped). See the HP manuals for more information about port naming conventions.

RAID protocols supported  Top

gFiler gateways support storage subsystems that use the RAID-1, RAID-5, and RAID-10 protocols, although the gFiler gateways do not themselves use RAID-1, RAID-5, or RAID-10. The following illustration provides a conceptual view of RAID-0 used on the gFiler and the RAID-1, RAID-5, and RAID-10 storage subsystems.

The gFiler stripes across LUNs in RAID-0, thereby maximizing performance because it is using more spindles. Another benefit of the gFiler using RAID-0 for striping across LUNs is that you can add LUNs to a NetApp volume.

There is no need for the gFiler to provide disk protection. The LUNs are already protected with the redundancy provided by RAID-1, RAID-5, and RAID-10 on the storage systems.

Note
NetApp filers use the RAID-4 protocol for disk protection. The RAID-4 protocol is not needed for gFiler gateways because the storage subsystems provide disk protection. Most of the disk information in the Data ONTAP documentation does not apply to the gFiler because it is about RAID-4 and RAID DP.

RAID group  Top

A NetApp aggregate or traditional volume is composed of one or more NetApp RAID (Redundant Array of Independent Disks) groups. From the perspective of gFiler gateways, Data ONTAP uses RAID groups to determine where to allocate data to the LUNs. (From the perspective of NetApp filers, a RAID group is composed of one or more data disks, across which client data is striped and stored, plus one or two parity disks that ensure data recoverability even if as many as two disks within the RAID group fail.)

You cannot assign a RAID group to more than one traditional volume or aggregate.

redundant port pairs  Top

The redundant paths to the same set of LUNs that go through two different ports.

Volume  Top

For XP storage subsystems, volume is synonymous with LDEV.

In Data ONTAP, volumes are the primary means of organizing and managing data. You can think about a volume as a container for storing data. You identify the collection of LUNs that are to be in the volume (where collection could mean only one LUN); those LUNs provide the capability for data storage. You manage data storage by managing volumes through the Data ONTAP system administration interface.

The capability of associating LUNs with volumes provides you a great deal of flexibility for data management. For example, you could create volumes to accommodate your users if they speak more than one language; you could create one volume for data in French and another for data in German. Alternatively, you can include all LUNs in one volume, the root volume that the gFiler setup process creates. The gFiler Software Installation, Setup, and Management Guide contains information about volume management.

Relationship of RAID groups to volumes

A NetApp volume is composed of one or more NetApp RAID groups.

The following illustration shows the components of a volume from the filer perspective--each volume is made up of one or more RAID groups, which are made up of one or more disks.

Note
The volume discussed is a RAID-4 volume, not RAID DP.

The following illustration shows the concept of the components of a volume from the perspective of a storage subsystem--each NetApp volume is made up of one or more LUNs in one or more RAID groups.

Library Table of Contents Index Previous Page (Alt-p) Next Page (Alt-n) Comments