Library Table of Contents Index Previous Page (Alt-p) Next Page (Alt-n) Comments

Switch-attached cluster configuration--513 to 672 LUNs

Connectivity overview  Top

The following information is for a switch-attached cluster configuration of 513 to 672 LUNs. The illustration and table show the number of ports and cable connections required for storage subsystems that support a maximum of 256 LUNs per port or 256 LUNs per host group per port (see Storage subsystem port support, by model).

Ports and connections

Number

gFiler HBA ports used

4 (2 each node)

Storage subsystem ports used

6 (3 each CL)

Switch ports used

10

Total cable connections

12, including cluster interconnect cables

Notes to the illustration:

Port-to-port connectivity  Top

The following table summarizes the port-to-port connectivity scheme for this configuration example for between 513 and 672 LUNs.

Port-to-port connectivity scheme

gFiler 1

Switch

1A

Any port on switch 1

2B

Any port on switch 2

gFiler 2

Switch

1A

Any port on switch 1

2B

Any port on switch 2

Storage subsystem

Switch

CL1-A

Any port on switch 1

CL1-B

Any port on switch 1

CL1-C

Any port on switch 1

CL2-A

Any port on switch 2

CL2-B

Any port on switch 2

CL2-C

Any port on switch 2

Library Table of Contents Index Previous Page (Alt-p) Next Page (Alt-n) Comments