Library Table of Contents Index Previous Page (Alt-p) Next Page (Alt-n) Comments

Direct-attached cluster configuration--2 to 256 LUNs

About this section  Top

This section shows two different configuration schemes for 2 to 256 LUNs in a direct-attached cluster configuration scheme. The configuration for the GF270c differs from other gFiler models.

Connectivity overview--configuration 1  Top

The following information is for a direct-attached cluster configuration of a GF270c, which supports 42 LUNs. The illustration and table show the number of ports and cable connections required for the GF270c.

Ports and connections

Number

gFiler HBA ports used

2

Storage subsystem ports used

2

Total cable connections

2

Notes to the illustration:

Port-to-port connectivity  Top

The following table summarizes the port-to-port connectivity scheme for the previous illustration.

Port-to-port connectivity scheme

CPU module 1

Storage subsystem

1A

CL1-A

CPU module 2

Storage subsystem

1B

CL1-B

Connectivity overview--configuration 2  Top

The following information is for a direct-attached cluster configuration of 2 to 256 LUNs. The illustration and table show the number of ports and cable connections required for models other than the GF270c.

Ports and connections

Number

gFiler HBA ports used

4 (2 each node)

Storage subsystem ports used

4 (2 each CL)

Total cable connections

6, including cluster interconnect cables

Notes to the illustration:

Port-to-port connectivity  Top

The following table summarizes the port-to-port connectivity scheme for this configuration example for between 2 to 256 LUNs.

Port-to-port connectivity scheme

gFiler 1

Storage subsystem

1A

CL1-1A

2B

CL2-2A

gFiler 2

Storage subsystem

1A

CL1-1B

2B

CL2-2B