Guidelines for configuring ports on your storage subsystem

Redundant port configuration  Top

Always configure ports in pairs. Each port in a redundant pair of ports must be configured the same way.

Sharing LUNs in a parity group  Top

LUNs in a parity group can be shared between gFiler gateways and non-gFiler hosts.

gFiler sharing channel adapter ports with other hosts  Top

If you are using the host group feature on your storage subsystem, you can share channel adapter ports among gFiler gateways and non-gFiler hosts.

gFiler ports in a host group  Top

If you create a host group, include all ports of the gFiler or gFiler cluster in the host group. The gFiler is limited to one host group per port and the maximum number of LUNs per host group in that port. If this maximum number of LUNs is smaller than the maximum number of LUNs that the gFiler node or cluster needs, you must add more ports on the storage subsystem to obtain the maximum number of LUNs that the node can support. You cannot just add another host group on the existing port for the gFiler to increase the number of LUNs.

Preventing overwriting of data  Top

To prevent overwriting of data, gFiler gateways and non-gFiler hosts must not share each other's LUNs. You can prevent overwriting of data by other hosts by using one of the following methods:

Guidelines for configuring Fibre Channel ports  Top

After selecting the Fibre Channel port you want to configure, use the following guidelines to set port options on the UI of your storage subsystem.

Port parameter

Guideline

Port address

Any port address

Fibre Channel topology

Whether a fabric switch is used--Fabric ON or OFF

Select whether a fabric switch is used to connect the gFiler to the storage subsystem. If you use a fabric switch, select Fabric ON. If not, select Fabric OFF.

Connection type--Fibre Channel or Point-to-Point

Select whether the connection type is Fibre Channel or Point-to-Point. If you use a fabric switch, select point-to-point. If not, that is, if the gFiler is directly connected to the storage subsystem, select Fibre Channel.

Host speed--1 or 2 Gb/s, or Auto

Set channel speed to auto or 2 Gb/s.