Library Table of Contents Previous Page (Alt-p) Next Page (Alt-n) Comments

MetroCluster configuration

About MetroCluster configurations  Top

This section discusses how to configure your gateway in a MetroCluster configuration. The MetroCluster configuration expands on the switch-attached cluster configuration.

Also included in this section are rules for zoning switch ports, which is required for MetroCluster configurations.

Supported gateways  Top

The following gateways support the MetroCluster configuration:

Required adapters and hardware for connectivity  Top

You need the following adapters for a MetroCluster:

Connectivity overview  Top

The following table describes the number of ports and cable connections needed for a MetroCluster configuration.

Number of gateways

Number of storage subsystems

Number of switches

Number of ISL connected switches

Number of cables
from gateway to switch

2

2

4

2

18

4

2

4

2

24

Connecting a gateway  Top

Configuration A

The following diagram provides an example of how the GF825 and GF940 connect to your storage subsystem for maximum capacity.

Port-to-port connectivity  Top

The following port-to-port scheme supports a maximum of 448 LUNs for the GF940 and a maximum of 512 LUNs for the GF960 in a redundant configuration.

Port-to-port connectivity scheme

Gateway 1

Switch

Zone

FC HBA

1A

Any port on switch 1

Optional

2B

Any port on switch 2

VI-MC

A

Any port on switch 1

1

B

Any port on switch 2

2

Storage subsystem 1

Switch

Zone

CL1-A

Any port on switch 1

Optional

CL2-A

Any port on switch 2

Gateway 2

Switch

Zone

FC HBA

1A

Any port on switch 3

Optional

2B

Any port on switch 4

VI-MC

A

Any port on switch 3

1

B

Any port on switch 4

2

Storage subsystem 2

Switch

Zone

CL1-C

Any port on switch 3

Optional

CL2-D

Any port on switch 4

ISL connection

Zone

Any port on switch 1

Any port on switch 3

None

Any port on switch 2

Any port on switch 4

None

Configuration B

The following diagram provides an example of how the GF960 connects to your storage subsystem for a maximum of 672 LUNs.

Note
HBA connections must never share the same zone as VI-MC connections. Zoning individual HBA connections is not required.

The following illustration shows a MetroCluster configuration with two cluster nodes. Gateways 1 and 3 are partner nodes and gateways 2 and 4 are partner nodes.

Port-to-port connectivity  Top

The following port-to-port scheme supports a maximum of 672 LUNs in a redundant configuration.

Port-to-port scheme

First MetroCluster pair

Fabric 1

Gateway 1

Switch

Zone

FC HBA

1A

Any port on switch 1

Optional

2B

Any port on switch 2

VI-MC

A

Any port on switch 1

1

B

Any port on switch 2

2

Gateway 2

Switch

Zone

FC HBA

1A

Any port on switch 1

Optional

2B

Any port on switch 2

VI-MC

A

Any port on switch 1

3

B

Any port on switch 2

4

Storage subsystem 1

Switch

Zone

CL1-A

Any port on switch 1

Optional

CL2-A

Any port on switch 2

CL1-B

Any port on switch 1

CL2-B

Any port on switch 2

Second MetroCluster pair

Fabric 2

Gateway 3

Switch

Zone

FC HBA

1A

Any port on switch 3

Optional

2B

Any port on switch 4

VI-MC

A

Any port on switch 3

1

B

Any port on switch 4

2

Gateway 4

Switch

Zone

FC HBA

1A

Any port on switch 1

Optional

2B

Any port on switch 2

VI-MC

A

Any port on switch 1

3

B

Any port on switch 2

4

Storage subsystem 2

Switch

Zone

CL1-C

Any port on switch 3

Optional

CL2-D

Any port on switch 4

CL1-D

Any port on switch 3

CL2-C

Any port on switch 4

ISL connection

Zone

Any port on switch 1

Any port on switch 3

None

Any port on switch 2

Any port on switch 4

None

Caution
You can attach a standard cluster to either the first or second pair of MetroCluster gateways, but not to both pairs.

Library Table of Contents Previous Page (Alt-p) Next Page (Alt-n) Comments