Use the procedures in this section if you are doing either of the following:
The procedures for upgrading the GF800 series and GF900 series are different, so be sure to read the correct procedure.
If you want to upgrade a cluster by using the nondisruptive upgrade method, see Installing system firmware--nondisruptive cluster method.
To install the firmware/diagnostics service image on your GF800 series gFiler running as a single node or as a cluster node that you are upgrading using the standard upgrade method, complete the following steps.
| 1 |
If the gFiler is a partner in a cluster, disable the cluster by entering the following command at the console of one of the gFilers: Wait until you see the "Cluster takeover disabled" message before proceeding to the next step. |
| 2 | |
| 3 |
If you are running Data ONTAP 6.4.1, enter the following command at the gFiler console to format the service partition. If you are not running release 6.4.1, you can skip this step. On all platforms, "3:" is the third partition, the service partition. Caution |
| 4 |
At the console, enter the following command to copy the executables to the boot blocks of the gFiler's CompactFlash: Result:The download -d command provides an acknowledgment similar to the following when copying is finished, and then the gFiler prompt appears again. ........................................................ Note |
| 5 |
At the console, enter the following command to shut down the gFiler: |
| 6 | |
| 7 |
Immediately press Delete while the memory test is in progress to interrupt the boot process. If you do not see a message that says skip-autoboot, press Ctrl-Backspace the next time. Note Result: |
| 8 |
If you are upgrading the gFiler from 6.4.2x and the gFiler is in a cluster, enter the following command and record the value of the variable, which is either "high" or "low." If the gFiler is not part of a cluster, you can skip this step. Note |
| 9 |
The Updater program prompts you for whether to replace the diagnostic program. |
| 10 |
The Updater program checks for a proper image. If the image is valid, it writes the flash. When fw_i1.rom finishes writing, it ends with the ok prompt. |
| 11 | |
| 12 |
Immediately press Delete while the memory test is in progress to interrupt the boot process. |
| 13 |
The Updater program prompts you for whether you want to update the flash. |
| 14 |
The Updater program checks for a proper image. If the image is valid, it updates the diagnostics program.When the diagnostics program has been updated, it ends with the ok prompt. Note |
| 15 |
If you are upgrading from firmware 4.3 or later, enter the following command: This command restores the environment variables to their default settings. |
| 16 | |
| 17 |
Immediately press Delete while the memory test is in progress to interrupt the boot process. |
| 18 |
If you are upgrading the gFiler from 6.4.2x and the gFiler is in a cluster
If the gFiler is not in a cluster, skip this step. |
| 19 |
If the gFiler is in a cluster, enter the following command to reenable the cluster: |
| 20 |
Proceed to Chapter 3, Upgrading Data ONTAP on the gFiler. |
To install the firmware/diagnostics service image on your GF900 series gFiler running as a single node or in a standard cluster, complete the following steps.
| 1 |
If the gFiler is in a cluster, disable the cluster by entering the following command at the console of one of the gFilers: Wait until you see the "Cluster takeover disabled" message before proceeding to the next step. |
| 2 | |
| 3 |
If you are running Data ONTAP 6.4.1, enter the following command at the gFiler console to manually format the service partition. If you are not running 6.4.1, you can skip this step. On all platforms, "3:" is the third partition, the service partition. Caution |
| 4 |
At the console, enter the following command to copy the executables to the boot blocks of the gFiler's CompactFlash card: Result:The download -d command provides an acknowledgment similar to the following when copying is finished, and then the gFiler prompt appears again. ........................................................ Note |
| 5 |
At the console, enter the following command to shut down the gFiler: |
| 6 | |
| 7 |
Immediately press Delete while the memory test is in progress to interrupt the boot process. If you do not see a message that says skip-autoboot, press Ctrl-Backspace the next time. Note Result: |
| 8 |
If you are upgrading the gFiler from 6.4.2x and the gFiler is in a cluster, enter the following command and record the value of the variable for each partner, which is either "high" or "low." If the gFiler is not in a cluster, skip this step. |
| 9 |
When the Updater program prompts you for whether you want to update the flash. ResultThe Updater program checks for a proper image. If the image is valid, the program writes the flash. When fw_i2.rom finishes writing, it ends with the ok prompt. Note |
| 10 |
If you are upgrading from firmware 4.3 or later, enter the following command: This command restores the environment variables to their default settings. |
| 11 | |
| 12 |
Immediately press Delete while the memory test is in progress to interrupt the boot process. If you do not see a message that says skip-autoboot, press Ctrl-Backspace the next time. Note |
| 13 |
If you are upgrading the gFiler from 6.4.2x and the gFiler is in a cluster, enter the following command: value is either high or low, whichever value you recorded in Step 8. |
| 14 |
Enter the following command to reboot the gFiler with the new system firmware and diagnostics: |
| 15 |
If your node is in a cluster, enter the following command to reenable the cluster: |
| 16 |
Proceed to Chapter 3, Upgrading Data ONTAP on the gFiler. |