NetApp recommends that you use the nondisruptive upgrade procedure to minimize service disruption in your clusters when you are upgrading Data ONTAP within a release family.
Note
You cannot use the nondisruptive upgrade method if you are upgrading between release families, for example, from 6.4.1 to 6.5.1. At this time, this feature is supported only in the 6.5 release family; 6.5 and 6.5x and 6.5.1 are in the same release family.
System firmware and some hardware upgrades can be performed at the same time as Data ONTAP software upgrades.
To download Data ONTAP to clustered gFilers by using the nondisruptive upgrade method, complete the following steps at the console of one of the gFilers in the cluster.
| 1 |
Ensure that you transferred the Data ONTAP software onto the gFiler, as described earlier in this chapter. | |
| 2 |
At the console of gFiler A, enter the following command to copy the executables to the boot blocks of the gFiler: download ResultThe download command provides an acknowledgment similar to the following: download: Reminder: upgrade both the nodes in the Cluster download: You can cancel this operation by hitting Ctrl-C in the next 6 seconds. download: Depending on system load, it may take many minutes download: to complete this operation. Until it finishes, download: you will not be able to use the console. Fri Mar 26 15:04:06 PST [raid-u20: download.request:notice]: Operator requested download initiated download: Downloading boot device ............................ download: Downloading boot device (Service Area) ....................................... download: Downloading disks: opening netapp_6.5.1 done download: boot blocks successfully copied to disk(s) raid-u20> Fri Mar 26 15:09:25 PST [raid-u20: download.requestDone:notice]: Operator requested download completed | |
| 3 | ||
|
Go to Step 4. | ||
cifs terminate -t nn nn is a notification period appropriate for your clients. After that period of time, proceed to Step 4. | ||
| 4 |
At the console of gFiler B, enter the following command: cf takeover ResultThis command causes gFiler A to shut down gracefully and leaves gFiler B in takeover mode. Note:At this point, you could perform a hardware upgrade procedure. To do so, you would do the following: | |
| 5 |
When you see the message on gFiler A, Waiting for giveback, go to Step 6. | |
| 6 |
At the console of gFiler B, enter the following command: cf giveback ResultThis command causes gFiler A to reboot with the new Data ONTAP version and resume normal operation as a cluster partner. Note | |
| 7 |
Repeat Step 1 through Step 6 to update the partner gFiler; that is, shut down and update gFiler B with partner A in takeover mode. | |
| 8 |
As needed, perform the procedures described in Concluding the upgrade. | |
Copyright © 1994-2004, Network Appliance, Inc. All rights
reserved.
Part No. 210-00662
File: ug_sw9.htm
Last updated: 04/12/04 17:11:48