Planning for gFilers with FC-AL adapters
Upgrade issues for gFilers with FC-AL adapters
If your gFiler has FC-AL adapters, you might need to change the jumpers on the adapter when you upgrade. For gFilers, an FC-AL adapter is the Fibre Channel Host Bus Adapter (HBA) that connects to your storage subsystem.
If the gFiler is running Data ONTAP release...
|
Then...
|
|
6.5 or later
|
The operation can be 1 Gb and 2 Gb or 1 Gb only. You do not need to change adapter settings.
|
|
6.4, 6.4.1, 6.4.2x*
|
The operation must be 1 Gb only--the jumper must be on pins 2 and 3 no matter what firmware version is running on the gFiler.
|
* Data ONTAP 6.4.3 and 6.4.4 are not supported on gFilers. For filers running Data ONTAP 6.4.3 or 6.4.4, the operation can be 1 Gb and 2 Gb or 1 Gb only.
Configuring FC-AL adapters on the gFiler
The procedure described in this section applies if the FC-AL adapters on your gFiler have the following marketing and spare part numbers:
- X2050A (SP-2050A)--Connects to storage
- X2051A (SP-2051A)--Connects to a tape backup device
To configure FC-AL adapters, complete the following steps, using the figure for reference.
Note
Do not apply any configuration changes to FCP target-mode adapters.
Step
|
Action
|
|
1
|
Verify that your system is running the correct software and, if applicable, the correct firmware for your FC-AL adapter configuration.
Caution You must verify the software and firmware requirements of your system. Having the incorrect software or firmware version on your system might cause your FC-AL adapters to function improperly.
|
|
2
|
Wearing an antistatic grounding leash, carefully remove the new FC-AL adapter from the plastic bag.
If you are configuring existing FC-AL adapters in your system, remove these adapters from your system chassis, as described in your hardware guide.
Caution Do not remove your FCP target-mode adapters or change the jumper settings on your FCP target-mode adapters.
|
|
3
|
If you are configuring your FC-AL adapter for...
|
Then...
|
|
1 Gb and 2 Gb operations
|
(Optional) Verify that both jumpers are on pins 1 and 2. If not, change the jumpers to pins 1 and 2.
|
|
1 Gb operation only
Note This configuration requires that all devices connected to your FC-AL adapters are configured for 1 Gb operation.
|
Verify that both jumpers are on pins 2 and 3. If not, change the jumper to pins 2 and 3.
|
|
4
|
Verify that both jumper posts J3 and J4 on the adapter have the same jumper settings.
Caution Your FC-AL adapter does not function properly if the two jumper posts have different jumper settings.
|
|
5
|
Install your FC-AL adapter, as described in your gFiler hardware guide.
|
Copyright © 1994-2004, Network Appliance, Inc. All rights
reserved.
Part No. 210-00662
File: upgrade7.htm
Last updated: 04/12/04 17:11:45