To configure the Brocade 3800, 3850, 3200, or 3250 switch for clustering, complete the following steps.
| 1 |
Log in to the switch, using the console port and hyperterm, and set the appropriate variables and IP addresses, as described in the appropriate Brocade switch hardware reference manual. Note |
|
| 2 |
Check the switch firmware by entering the following command: version Result |
|
| 3 |
Check the MetroCluster Fabric Switch download page on http://now.netapp.com for the currently supported version of the switch firmware. Note |
|
| 4 | ||
|
Go to Step 5. | ||
| 5 |
Disable the switch by entering the following command: switchdisable |
|
| 6 |
Clear any existing configuration on the switch by entering the following command: cfgclear |
|
| 7 |
Disable the configuration by entering the following command: cfgdisable |
|
| 8 |
Save the configuration by entering the following command: |
|
| 9 |
Ensure that the switch is configured with default settings by entering the following command: configdefault |
|
| 10 |
Set the switch parameters by entering the following command: configure You should set the following parameters only: |
|
| 11 |
Exit the configuration utility by entering the following command: ctrl-d |
|
| 12 |
Reboot the switch so that the default settings take effect by entering the following command: fastboot |
|
| 13 |
Log in to the switch and disable the switch by entering the following command: switchdisable |
|
| 14 |
Set the switch port speeds to half duplex by entering the following command for each switch port into which a disk is plugged: portcfglport <port#>,0,0,1 Note |
|
| 15 | ||
|
Set the ISL port distance on each ISL port to short distance by entering the following command: | ||
|
Set the ISL port distance on each ISL port to long distance by entering the following command: | ||
| 16 |
Enable the switch by entering the following command: switchenable |
|
| 17 |
Set the switch name by entering the following command: switchname "Metro1_sw1" Metro1_sw1 is the name given to the current switch. Use a meaningful name up to 12 characters long. |
|
| 18 |
Check the switch settings by entering the following command: configshow |
|
| 19 |
Repeat Step 1 through Step 18 for the second switch on the local node. |
|
| 20 | ||
Copyright © 1994-2005, Network Appliance, Inc. All rights
reserved.
Part No. 210-01386_C0
File: ch3_mci5.htm
Last updated: 21-Dec-2005 11:31:57