Correcting takeover or giveback failures

About this section  Top

The procedure for correcting a takeover or giveback failure on an F800 series cluster is different from that of a FAS900 and FAS3000 series cluster. See one of the following sections according to your system hardware:

Troubleshooting F800 series takeover or giveback failures  Top

If takeover or giveback fails on an F800 series cluster, complete the following steps.

Step

Action

1

Check the Channel B cabling on the disk shelves, and tighten any loose cables.

2

Check the cabling to your cluster adapters, making sure that the cabling is correct, that the cables are properly seated in the adapters, and that the cables are secured to the adapters.

3

Check communication between the nodes by entering the following command:

cf status

Result

If there is a cabling error or the interconnect link is down, the system displays an error message indicating the error.

4

If you have not already done so, run the Cluster Configuration Checker utility.

For details, see Checking cluster configuration.

5

Check network connectivity.

For details, see the Data ONTAP Network Administration Guide.

6

Reboot the cluster and rerun the takeover and giveback tests.

7

If you still do not have clustering enabled, contact technical support.

Troubleshooting FAS900 and FAS3000 series takeover or giveback failures  Top

If takeover or giveback fails on a FAS900 series or FAS3000 series cluster, complete the following steps.

Note
You must reboot the cluster after completing each test.

To correct a takeover or giveback failure, complete the following steps.

Step

Action

1

Check communication between the local and partner nodes by entering the following command and observing the messages:

cf status

Result

If there is a problem with cabling or the adapter, the appropriate message is displayed. Recable or replace the cluster adapter, as needed.

2

If the error message indicates...

Then...

A cluster adapter error

Check the cluster adapter cabling. Make sure that the cabling is correct and properly seated at both ends of the cable.

That the NVRAM5 adapter is in the wrong slot number

Check the NVRAM5 slot number. Move it to the correct slot if it is in the wrong one.

A Channel B cabling error

Check the cabling of the Channel B disk shelf loops and reseat and tighten any loose cables.

A networking error

Check for network connectivity.

See the Network Administration Guide for more information.

3

If you have not already done so, run the Cluster Configuration Checker script, as described in Checking cluster configuration.

Correct any errors or differences displayed in the output.

4

Reboot the cluster and rerun the takeover and giveback tests.

5

If you still do not have clustering enabled, contact technical support.