The conditions under which takeovers occur depend on how you configure the cluster. For more information about configuring a cluster for takeover, see Configuring when takeover occurs. Takeovers can be initiated when one of the following conditions occur:
Note
If the storage for a node also loses power at the same time, a standard takeover is not possible. For MetroClusters, you can initiate a forced takeover in this situation.
When a takeover occurs, the unimpaired partner node in the cluster takes over the functions and disk drives of the failed node by creating an emulated storage system that
The partner node maintains its own identity and its own primary functions, but also handles the added functionality of the failed node through the emulated node.
Note
When a takeover occurs, existing CIFS sessions are terminated. A graceful shutdown of the CIFS sessions is not possible, and some data loss could occur for CIFS users.
After a takeover occurs, you view the surviving partner as having two identities, its own and its partner's, that exist simultaneously on the same storage system. Each identity can access only the appropriate volumes and networks. You can send commands or log in to either storage system by using the rsh command, allowing remote scripts that invoke storage system commands through a Remote Shell connection to continue to operate normally.
Commands sent to the failed node through a Remote Shell connection are serviced by the partner node, as are rsh command login requests.
If you log in to a failed node through a Telnet session, you see a message alerting you that your storage system failed and to log in to the partner node instead. If you are logged in to the partner node, you can access the failed node or its resources from the partner node by using the partner command.
When the failed node is functioning again
Copyright © 1994-2005, Network Appliance, Inc. All rights
reserved.
Part No. 210-01386_C0
File: ch5_mgn2.htm
Last updated: 21-Dec-2005 11:32:00