This section provides information about how to hot-add a DS14, DS14mk2 FC, or DS14mk2 AT disk shelf to an existing loop. It also tabulates the error messages that appear on your storage system console if the attempt at hot-adding was unsuccessful.
Note
The hot-added disk shelf must have new drives that will be used as spares only.
To hot-add a DS14, DS14mk2 FC, or DS14mk2 AT to an existing loop, the following requirements must be met.
| |
|
The disk shelves in the existing loop must have only DS14, DS14mk2 FC, or DS14mk2 AT disk shelves with ESH or ESH2 modules in the loop. | |
|
The disk shelves in the existing loop must have only DS14mk2 AT disk shelves with AT-FCX modules in the loop. |
To hot-add a disk shelf to an existing loop, complete the following steps.
| 1 | ||
| 2 |
See the DiskShelf14, DiskShelf14mk2 FC, or DiskShelf14mk2 AT Hardware Guide for more information. |
|
| 3 |
Ground the disk shelf using the provided grounding cable. See the DiskShelf14, DiskShelf14mk2 FC, or DiskShelf14mk2 AT Hardware Guide for more information. |
|
| 4 |
Connect the disk shelf to a power source. See the DiskShelf14, DiskShelf14mk2 FC, or DiskShelf14mk2 AT Hardware Guide for more information. |
|
| 5 |
Give the disk shelf a unique disk shelf ID. See the DiskShelf14, DiskShelf14mk2 FC, or DiskShelf14mk2 AT Hardware Guide for more information. Note |
|
| 6 |
Verify that the disk shelf ID is not being used in the loop by entering the following command at the console: fcstat device_map adaptername Attention |
|
| 7 | ||
| ||
| ||
| 8 | ||
|
Turn on the power to the disk shelf and wait 60 seconds for the electronics to finish initializing. | ||
|
Turn on the power to the disk shelf and wait 60 seconds for the electronics to finish initializing. Attention | ||
|
Turn on the power to the disk shelf and wait 60 seconds for the electronics to finish initializing. Note | ||
| 9 |
Connect one end of the provided cable to the LRC, ESH, ESH2, or AT-FCX Channel A Input on the new disk shelf. |
|
| 10 |
Connect the other end of the cable to the LRC, ESH, ESH2, or AT-FCX Channel A Output on the last disk shelf in the existing loop. |
|
| 11 |
Connect one end of the provided cable to the LRC, ESH, ESH2, or AT-FCX Channel B Input on the new disk shelf. |
|
| 12 |
Connect the other end of the cable to the LRC, ESH, ESH2, or AT-FCX Channel B Output on the last disk shelf in the existing loop. |
|
| 13 |
Verify that all the cables are securely fastened. Attention |
|
| 14 | ||
ResultIn 60 seconds, the storage system recognizes the hot-added disk shelf. | ||
ResultIn 60 seconds, the storage system recognizes the hot-added disk shelf. | ||
The following error messages appear on your storage system console if your attempt at hot-adding the DS14/DS14mk2 FC is unsuccessful.
Copyright © 1994-2005, Network Appliance, Inc. All rights
reserved.
Part No. 210-01386_C0
File: ch7_trb4.htm
Last updated: 21-Dec-2005 11:32:05