If your cluster has disk shelves that have LRC modules and you add a DS14/DS14mk2 FC disk shelf that has ESH or ESH2 modules, you need to replace the LRC modules with ESH or ESH2 modules in the existing DS14 disk shelves.
The following table describes which types of hot-upgrade and hot-downgrade each type of diskshelf supports.
Attention
You must hot-upgrade or hot-downgrade all disk shelves in the loop.
|
To upgrade your DS14/DS14mk2 FC disk shelves to use ESH or ESH2 modules, complete the following steps. Keep in mind that at any given time a storage system that is up and running needs to have at least one path to any shelf.
Note
Do not mix LRC and ESH modules in the same loop; loop failure results.
Replacing an ESH with an ESH2 requires that you upgrade to Data ONTAP 6.4.4 or later, and replace both ESH modules in the disk shelf with ESH2 modules.
For more information about upgrading disk shelves, see the DiskShelf14, DiskShelf14mk2 FC, or DiskShelf14mk2 AT Hardware Guide.
| 1 |
Determine which loop you will upgrade first, and determine whether any disks in the cluster are single-pathed through that loop. For more information, see How to determine path status for your cluster. |
|
| 2 |
If any disks use this loop for their only path to a controller, complete the following steps: ResultYou can now replace all modules on all loops attached to Node B. |
|
| 3 |
Note the terminate switch position of the LRCs you are replacing in this loop. If the new modules have terminate switches, they should be set to the same setting as the LRCs they are replacing. Note |
|
| 4 |
While grounded, unplug the cabling from the dormant loop and note the cable locations. |
|
| 5 |
Remove the LRC modules from the disk shelves that do not have a cable attached. |
|
| 6 |
Insert all of the new modules. Attention |
|
| 7 | ||
| 8 |
Check the operation of the new modules by entering the following command from the console of the node that is still running: environ shelf ResultThe node reports the status of the modified shelves as good. |
|
| 9 |
If there is more than one loop attached to the node that has been taken over, repeat Step 3 through Step 8 for all other loops on that node. |
|
| 10 |
If you performed a cluster takeover previously, complete the following steps: |
|
| 11 |
Check the operation of the new modules by entering the following command on the console of both nodes: environ shelf ResultEach node reports the status of the modified shelves as good. |
|
| 12 |
Check the next loop you will upgrade to determine whether any disks in the cluster are single-pathed through that loop. For more information, see How to determine path status for your cluster |
|
| 13 |
If any disks use this loop for their only path to a controller, complete the following steps: ResultYou can now replace all modules on all loops attached to Node A. |
|
| 14 |
Repeat Step 3 through Step 11, with Node B as the takeover node. |
|
| 15 |
Test the upgraded modules, as described in Testing the modules. |
|
| 16 |
Test the configuration, as described in Stage 6: Checking and testing cluster configuration. |
|