You use this procedure when you need to replace a faulty module.
Note
When you hot-swap a LRC, ESH, ESH2, or AT-FCX module, you must ensure that you never disable the only path to a disk, which will result in a system outage.
For more information, see Understanding single and dual pathing in clusters.
To hot-swap a single module, complete the following steps.
| 1 |
Verify that your storage system meets the minimum software requirements to support the disk shelf modules that you are hot-swapping. See the DiskShelf14, DiskShelf14mk2 FC, or DiskShelf14mk2 AT Hardware Guide for more information. |
|
| 2 |
Determine which loop contains the module you are removing, and determine whether any disks in the cluster are single-pathed through that loop. For more information, see How to determine path status for your cluster. |
|
| 3 |
If you performed a cluster takeover previously, complete the following steps: |
|
| 4 |
If any disks use this loop for their only path to a controller, complete the following steps:
ResultThe modules in the loop that are attached to Node A can now be replaced. |
|
| 5 | ||
| 6 |
Disconnect the module that you are removing from the Fibre Channel cabling. |
|
| 7 |
Using the thumb and index finger of both hands, press the levers on the CAM mechanism on the module to release it and pull it out of the disk shelf. |
|
| 8 |
Slide the replacement module into the slot at the rear of the disk shelf and push the levers of the CAM mechanism into place. Attention |
|
| 9 | ||
| 10 |
Check the operation of the new modules by entering the following command from the console of both nodes: environ shelf |
|
| 11 |
Test the replacement module, as described in Testing the modules. |
|
| 12 |
Test the configuration, as described in Stage 6: Checking and testing cluster configuration. |
|