This section provides information about how to hot-add a DS14mk2 AT to an existing loop. It also tabulates the error messages that appear on your storage appliance console if the attempt at hot-adding was unsuccessful.
The following requirements must be met when hot-adding a DS14mk2 AT to an existing loop:
To hot-add a disk shelf to an existing loop, complete the following steps.
Caution
To hot-add disk shelves to a cluster, see the cluster guide for your storage appliance.
| 1 |
Ground yourself to the system chassis using the grounding leash. |
| 2 |
Follow Step 3 through Step 9 of Installing a disk shelf. |
| 3 |
Connect the two disk shelf power cords to each disk shelf that you are adding. Caution |
| 4 |
Verify that the disk shelf ID is not being used in the loop by entering the following command at the console: fcstat device_map adaptername Caution |
| 5 |
Turn on the power to the disk shelf and you must wait 30 seconds for the shelf electronics to finish initializing. |
| 6 |
Perform Step 7 through Step 10 exactly. Note |
| 7 |
Connect one end of the cable to the AT-FCX A Input on the new disk shelf. |
| 8 |
Connect the other end of the provided cable to the AT-FCX A Output on the last disk shelf in the existing loop. |
| 9 |
Connect one end of the cable to the AT-FCX B Input on the new disk shelf. |
| 10 |
Connectthe other end of the provided cable to the AT-FCX B Output on the last disk shelf in the existing loop. |
| 11 |
Verify that all the cables are securely fastened. Caution ResultIn 60 seconds, the storage appliance recognizes the hot-added disk shelf. |
The following error messages appear on your storage appliance console if your attempt at hot-adding the DS14mk2 AT is unsuccessful.
Open loop panic | |
Soft address panic |
Copyright © 1994-2005, Network Appliance, Inc. All rights
reserved.
Part No. 210-02360
File: appa2.htm