Library Table of Contents Index Previous Page (Alt-p) Next Page (Alt-n) Comments

Monitoring the AT-FCX module

About monitoring the modules  Top

The AT-FCX module has four LEDs. The LEDs indicate whether it is functioning normally, the module's readiness for I/O traffic, or whether there are any problems with the hardware. You can also identify any hardware failure associated with the module from the error messages displayed on your storage appliance console.

This section also describes the different types of messages that appear on the storage appliance console in response to a command monitoring the AT-FCX.

Location of the module LEDs  Top

The AT-FCX module is in the middle of the back of the disk shelf. It has a perforated carrier. The following illustration shows the location of the LEDs for an AT-FCX.

Note
Because module A on the DS14mk2 AT is inverted, the location of the module A LEDs is the inverse of what is shown in the preceding illustration. The Fault LED is amber. The other three LEDs are green. See LED status on the AT-FCX for an illustrated explanation of the LED functions.

LED status on the AT-FCX  Top

The following illustration is of the second sheet of the quick reference cards that come with your disk shelf.

Note
The rest of the second sheet of the quick reference card identifies the LED status conditions for the power supply and the integrated fan module.

AT-FCX console error messages  Top

The following error messages appear on the storage appliance console if an SES element on the AT-FCX module fails. See Hot-Swapping the AT-FCX module for more information. The output displayed on the console is similar to the following example.

Example

Mon Aug 25 21:34:05 GMT [ses.status.temperatureWarning:warning]: 
DS14-Mk2-AT shelf 3 on channel 5a temperature warning for 
Temperature sensor 1: non-critical status; undertemperature 
warning. Current temperature: 1 C (33 F). This module is on the 
front side of the shelf, at the right, on the OPS panel.

Error message

Corrective action

Temperature sensor 2: failed

Contact NetApp technical support.

Temperature sensor 3: failed
SES electronics Element 1: 
component is from a different 
product family

This configuration is unsupported. Contact NetApp technical support.

SES electronics Element 1: 
failed

Contact NetApp technical support.

SES electronics Element 2: 
failed

The AT-FCX module on the disk shelf failed. Replace the AT-FCX module, as described in Hot-Swapping the AT-FCX module.

Temperature sensor 2: not 
installed or failed

Contact NetApp technical support.

Environmental sensor 3: not 
installed or failed

Contact NetApp technical support.

SES electronics Element 1: 
not installed or failed
Vendor-specific Element 1: 
not installed or failed
SES electronics Element 2: 
not installed or failed

Communication with the temperature sensor on the AT-FCX module failed. Replace the AT-FCX module, as described in Hot-Swapping the AT-FCX module.

Vendor-specific Element 2: 
not installed or failed

Library Table of Contents Index Previous Page (Alt-p) Next Page (Alt-n) Comments