The assumptions about this procedure are that LRC/ESH/ESH2 modules on the disk shelf are multipath connections to the storage appliance and that you are hot-swapping an LRC with another LRC, an ESH with another ESH, an ESH2 with another ESH2, or that you are hot-swapping an ESH with an ESH2.
Note
A hot-swap of an ESH with an ESH2 requires that you upgrade to Data ONTAP 6.4.4 or later and replace both ESH modules in the disk shelf. A hot-swap of an ESH with an ESH2 is not supported with NetCache appliances.
If you are hot-upgrading or hot-downgrading these devices, see Hot-upgrading or hot-downgrading a disk shelf.
Caution
If you attempt to hot-swap the LRC/ESH/ESH2 on a disk shelf that does not have multipath connections, you lose all access to the drives on this disk shelf as well as those below it.
To hot-swap a module, complete the following steps.
Note
To hot-swap a module on a disk shelf in a cluster, see the cluster guide for your filer.
| 1 |
Verify that your NetApp appliance meets the minimum software requirements to support the disk shelf and module combination. See the System Configuration Guide at http://now.netapp.com for more information. |
|
| 2 | ||
| 3 |
From the console of the storage appliance, enter the following command to disable the loop in which the failed module is a connection: storage disable adapter adaptername The Data ONTAP System Administrator's Guide (6.1 or later) provides more information about these commands. |
|
| 4 | ||
|
Note the position of the terminate switch on the LRC/ESH you are removing and set the terminate switch on the replacement LRC/ESH to the same setting before inserting it into the disk shelf. | ||
| ||
|
On all the disk shelves in the loop, place the terminate switch to the Off position. For ESH A it is in the down position and for ESH B it is in the up position. | ||
|
An ESH2 with an ESH2 |
Go to Step 5. | |
| 5 | ||
|
Disconnect the module that you are removing from the Fibre Channel cabling. | ||
|
Disconnect the ESH from the Fibre Channel cabling and remove the cabling. | ||
| 6 |
Using the thumb and index finger of both hands, press the levers on the CAM mechanism on the module to release it and pull it out of the disk shelf. |
|
| 7 |
Slide the module into the slot at the rear of the disk shelf and push the levers of the CAM into place. Caution |
|
| 8 | ||
|
Use HSSDC2-to-SFP cables for connections between a disk shelf with ESH and a disk shelf with ESH2. Note |
||
| 9 |
From the console of the filer, enter the following command to enable the loop in which the replacement LRC/ESH/ESH2 is a connection: storage enable adapter adaptername |
|
| 10 | ||
Copyright © 1994-2005, Network Appliance, Inc. All rights
reserved.
Part No. 210-00765
File: device10.htm
Last updated: Mon Apr 11 15:36:36 2005