Operational Error Messages
When operational error messages appear
These error messages might appear on the system console or LCD when the system is operating, when it is halted, or when it is restarting because of system problems.
Operational error messages
The following table describes operational error messages that might appear on the LCD if your appliance encounters errors while starting up or during operation.
Error message
|
Explanation
|
Fatal?
|
Corrective action
|
|
Disk n is broken
|
n--The RAID group disk number. The solution depends on whether you have a hot spare in the system.
|
No
|
See the appropriate system administration guide for information about how to locate a disk based on the RAID group disk number and how to replace a faulty disk.
|
|
Dumping core
|
The system is dumping core after a system crash.
|
Yes
|
Write down the system crash message on the system console and report the problem to NetApp technical support.
|
|
Disk hung during swap
|
A disk error occurred as you were hot-swapping a disk.
|
Yes
|
- Disconnect the disk from
the power supply by
opening the latch and
pulling it half-way out.
- Wait 15 seconds to allow all
disks to spin down.
- Reinstall the disk.
- Restart the system by
entering the following
command:
boot
|
|
Error dumping core
|
The system cannot dump core during a system crash and restarts without dumping core.
|
Yes
|
Report the problem to NetApp technical support.
|
|
Panicking
|
The system is crashing. If the system does not hang while crashing, the message Dumping core appears.
|
Yes
|
Report the problem to NetApp technical support.
|
Copyright © 1994-2005, Network Appliance, Inc. All rights
reserved.
Part No. 215-01469
File: op_err3.htm