Configuring the Fibre Channel port
Function of the ports
The FAS270/FAS270c CPU module provides two independent Fibre Channel ports, identified as 0b and 0c:
- You use the 0b port to communicate to internal and external disks.
- The 0c port has an external optical connector on the rear of the FAS270/FAS270c. You can configure the 0c port in one of two modes:
- You use initiator mode to communicate with tape backup devices, such as in a TapeSAN backup configuration.
- You use target mode to communicate with SAN hosts or a front end SAN switch.
Fibre Channel port 0c does not support mixed initiator/target mode. The default mode for port 0c is initiator mode. If you have not licensed the FCP service and you want to use port 0c in initiator mode, you do not need to configure the port.
FAS270c cluster configurations
FAS270c cluster configurations must be cabled to switches that support public loop topology. To connect a FAS270c to a fabric topology that includes switches that only support point-to-point topology, such as McDATA Director class switches, you must connect the cluster to an edge switch and use this switch as a bridge to the fabric. For information about specific switch models supported and fabric configuration guidelines, see the FCP/iSCSI Configuration Guide at http://now.netapp.com/NOW/ knowledge/docs/san/fcp_iscsi_config/.
Configuring port 0c for target mode
To configure the external Fibre Channel port 0c for target mode, complete the following steps.
Step
|
Action
|
|
1
|
Enable the FCP license by entering the following command:
license add FCP_code
FCP_code is the FCP service license code provided to you by NetApp.
Example
fas270a> license add XXXXXXX
A fcp site license has been installed.
cf.takeover.on_panic is changed to on
Run 'fcp start' to start the FCP service.
Also run 'lun setup' if necessary to configure LUNs.
A reboot is required for FCP service to become available.
FCP enabled.
fas270a> Fri Dec 5 14:54:24 EST [fas270a: rc:notice]: fcp licensed
|
|
2
|
Reboot the system by entering the following command:
reboot
|
|
3
|
Verify that Fibre Channel port 0c is in target mode by entering the following command:
sysconfig
Example
fas270a> sysconfig
NetApp Release R6.5xN_031130_2230: Mon Dec 1 00:07:33 PST 2003
System ID: 0084166059 (fas270a)
System Serial Number: 123456 (fas270a)
slot 0: System Board
Processors: 2
Processor revision: B2
Processor type: 1250
Memory Size: 1022 MB
slot 0: FC Host Adapter 0b
14 Disks: 952.0GB
1 shelf with EFH
slot 0: Fibre Channel Target Host Adapter 0c
slot 0: SB1250-Gigabit Dual Ethernet Controller
e0a MAC Address: 00:a0:98:01:29:cd (100tx-fd-up)
e0b MAC Address: 00:a0:98:01:29:ce (auto-unknown-cfg_down)
slot 0: NetApp ATA/IDE Adapter 0a (0x00000000000001f0)
0a.0 245MB
Note Fibre Channel port 0c is identified as Fibre Channel Target Host Adapter 0c.
|
|
4
|
Start the FCP service by entering the following command:
fcp start
Example
fas270a> fcp start
FCP service is running.
Wed Sep 17 15:17:04 GMT [fas270a: fcp.service.startup:info]: FCP service
startup
|
Changing port 0c back to initiator mode
To change the port 0c back to initiator mode from target mode, complete the following steps.
Step
|
Action
|
|
1
|
Remove the FCP license by entering the following command:
license delete fcp
Example
fas270a> license delete fcp
Fri Dec 5 14:59:02 EST [fas270a: fcp.service.shutdown:info]: FCP service
shutdown
cf.takeover.on_panic is changed to off
A reboot is required for TapeSAN service to become available.
unlicensed fcp.
FCP disabled.
fas270a> Fri Dec 5 14:59:02 EST [fas270a: rc:notice]: fcp unlicensed
|
|
2
|
Reboot the system by entering the following command:
reboot
|
|
3
|
After the reboot, verify that port 0c is in initiator mode by entering the following command:
sysconfig
Example
fas270a> sysconfig
NetApp Release RscrimshawN_030824_2300: Mon Aug 25 02:20:04 PDT 2003
System ID: 0084165669 (fas270a); partner ID: 0084165671 (fas270b)
System Serial Number: 379589 (fas270a)
slot 0: System Board
Processors: 2
Processor revision: B2
Processor type: 1250
Memory Size: 1022 MB
slot 0: FC Host Adapter 0b
14 Disks: 952.0GB
1 shelf with EFH
slot 0: FC Host Adapter 0c
slot 0: SB1250-Gigabit Dual Ethernet Controller
e0a MAC Address: 00:a0:98:00:d5:90 (100tx-fd-up)
e0b MAC Address: 00:a0:98:00:d5:91 (auto-unknown-cfg_down)
slot 0: NetApp ATA/IDE Adapter 0a (0x00000000000001f0)
0a.0 122MB
Note Fibre Channel port 0c is identified as FC Host Adapter 0c.
|
|
4
|
Enable port 0c by entering the following command.
storage enable adapter 0c
Example
fas270a> storage enable adapter 0c
Mon Dec 8 08:55:09 GMT [rc:notice]: Onlining Fibre Channel adapter 0c.
host adapter 0c enable succeeded
|
For more information
For more information about configuring your SAN, see the following resources:
- Fibre Channel Tape SAN Solutions at http://www.netapp.com/osn/info/config.html
- Data ONTAP System Administration FCP Block Access Management Guide
Copyright © 1994-2005, Network Appliance, Inc. All rights
reserved.
Part No. 210-01108-A0
File: configu7.htm
Last updated: Wed Apr 13 11:17:46 2005