Library Table of Contents Index Previous Page (Alt-p) Next Page (Alt-n) Comments

Configuring the Fibre Channel port

Function of the ports  Top

The FAS270/FAS270c CPU module provides two independent Fibre Channel ports, identified as 0b and 0c:

Fibre Channel port 0c does not support mixed initiator/target mode. The default mode for port 0c is initiator mode. If you have not licensed the FCP service and you want to use port 0c in initiator mode, you do not need to configure the port.

FAS270c cluster configurations  Top

FAS270c cluster configurations must be cabled to switches that support public loop topology. To connect a FAS270c to a fabric topology that includes switches that only support point-to-point topology, such as McDATA Director class switches, you must connect the cluster to an edge switch and use this switch as a bridge to the fabric. For information about specific switch models supported and fabric configuration guidelines, see the FCP/iSCSI Configuration Guide at http://now.netapp.com/NOW/ knowledge/docs/san/fcp_iscsi_config/.

Configuring port 0c for target mode  Top

To configure the external Fibre Channel port 0c for target mode, complete the following steps.

Step

Action

1

Enable the FCP license by entering the following command:

license add FCP_code

FCP_code is the FCP service license code provided to you by NetApp.

Example

fas270a> license add XXXXXXX 
A fcp site license has been installed.
cf.takeover.on_panic is changed to on
Run 'fcp start' to start the FCP service.
Also run 'lun setup' if necessary to configure LUNs.
A reboot is required for FCP service to become available.
        FCP enabled.
fas270a> Fri Dec  5 14:54:24 EST [fas270a: rc:notice]: fcp licensed
2

Reboot the system by entering the following command:

reboot
3

Verify that Fibre Channel port 0c is in target mode by entering the following command:

sysconfig 

Example

fas270a> sysconfig
        NetApp Release R6.5xN_031130_2230: Mon Dec  1 00:07:33 PST 2003
        System ID: 0084166059 (fas270a)
        System Serial Number: 123456 (fas270a)
        slot 0: System Board
                Processors:         2
                Processor revision: B2
                Processor type:     1250
                Memory Size:        1022 MB
        slot 0: FC Host Adapter 0b
                14 Disks:            952.0GB
                1 shelf with EFH
        slot 0: Fibre Channel Target Host Adapter 0c
        slot 0: SB1250-Gigabit Dual Ethernet Controller
                e0a MAC Address:    00:a0:98:01:29:cd (100tx-fd-up)
                e0b MAC Address:    00:a0:98:01:29:ce (auto-unknown-cfg_down)
        slot 0: NetApp ATA/IDE Adapter 0a (0x00000000000001f0)
                0a.0                 245MB

Note
Fibre Channel port 0c is identified as Fibre Channel Target Host Adapter 0c.

4

Start the FCP service by entering the following command:

fcp start

Example

fas270a> fcp start
FCP service is running.
Wed Sep 17 15:17:04 GMT [fas270a: fcp.service.startup:info]: FCP service 
startup

Changing port 0c back to initiator mode  Top

To change the port 0c back to initiator mode from target mode, complete the following steps.

Step

Action

1

Remove the FCP license by entering the following command:

license delete fcp

Example

fas270a> license delete fcp
Fri Dec  5 14:59:02 EST [fas270a: fcp.service.shutdown:info]: FCP service 
shutdown
cf.takeover.on_panic is changed to off
A reboot is required for TapeSAN service to become available.
unlicensed fcp.
        FCP disabled.
fas270a> Fri Dec  5 14:59:02 EST [fas270a: rc:notice]: fcp unlicensed
2

Reboot the system by entering the following command:

reboot
3

After the reboot, verify that port 0c is in initiator mode by entering the following command:

sysconfig 

Example

fas270a> sysconfig
        NetApp Release RscrimshawN_030824_2300: Mon Aug 25 02:20:04 PDT 2003
        System ID: 0084165669 (fas270a); partner ID: 0084165671 (fas270b)
        System Serial Number: 379589 (fas270a)
        slot 0: System Board
                Processors:         2
                Processor revision: B2
                Processor type:     1250
                Memory Size:        1022 MB
        slot 0: FC Host Adapter 0b 
                14 Disks:            952.0GB
                1 shelf with EFH
        slot 0: FC Host Adapter 0c 
        slot 0: SB1250-Gigabit Dual Ethernet Controller
                e0a MAC Address:    00:a0:98:00:d5:90 (100tx-fd-up)
                e0b MAC Address:    00:a0:98:00:d5:91 (auto-unknown-cfg_down)
        slot 0: NetApp ATA/IDE Adapter 0a (0x00000000000001f0)
                0a.0                 122MB

Note
Fibre Channel port 0c is identified as FC Host Adapter 0c.

4

Enable port 0c by entering the following command.

storage enable adapter 0c

Example

fas270a> storage enable adapter 0c
Mon Dec  8 08:55:09 GMT [rc:notice]: Onlining Fibre Channel adapter 0c.
host adapter 0c enable succeeded

For more information  Top

For more information about configuring your SAN, see the following resources:

Library Table of Contents Index Previous Page (Alt-p) Next Page (Alt-n) Comments