You can convert a FAS270/FAS270c system using disk shelves with LRC modules to one with disk shelves using ESH2 modules. You can convert a FAS270c system by hot-swapping the LRC with ESH2 modules; that is, by allowing the system to continue running without powering off. A FAS270 system, however, has a single loop, requiring that you take the system offline before converting the modules.
Caution
If you attempt to hot-swap the LRC module with an ESH2 module on a disk shelf that does not have multipath connections, you lose all access to the drives on that disk shelf as well as those connected below it.
To replace the LRC modules with ESH2 modules, complete the following steps.
| 1 |
Verify that your NetApp appliance meets the minimum software requirements to support the disk shelf and module combination. See the System Configuration Guide at http://now.netapp.com for more information. |
|
| 2 | ||
|
Power off your system and go to Step 6. | ||
|
Select which node/loop you want to convert first; A or B. For the sake of clarity, let's convert node/loop B in the following steps. | ||
| 3 |
From the node A console, enter the following command and observe the output: cf enable Result |
|
| 4 |
Enter the following command from the node A console: cf takeover ResultNode A takes over node B and gives the following output: takeover completed |
|
| 5 |
Make sure that node A can access both node B and node A disks. |
|
| 6 | ||
| 7 |
Disconnect the LRC modules from the Fibre Channel cabling on all disk shelves in the B loop, and remove the cabling from the system. |
|
| 8 |
Unlatch all LRC modules in the B loop. Using the thumb and index finger of both hands, press the levers on the CAM mechanism on the module to release it.
|
|
| 9 |
Pull all LRC modules in the B loop out of the disk shelf and set them aside. |
|
| 10 |
Install all replacement ESH2 modules into the B loop of the disk shelves. For each module, push apart the levers on the CAM mechanism and slide the replacement ESH2 module into the slot at the rear of the disk shelf, then push the levers of the CAM mechanism into place. Caution |
|
| 11 |
Plug the optical SFP into the input port on the ESH2 modules if they are not already plugged in.
|
|
| 12 |
Connect all ESH2 modules to your storage appliance. Note |
|
| 13 | ||
|
Give back the partner node by entering the following command: cf giveback ResultThe local node releases the partner node, which reboots and resumes normal operation. The following message is displayed on the console when the process is complete: giveback completed | ||
| 14 |
On FAS270c systems, repeat Step 3 through Step 13 for the second node/loop. |
|
Copyright © 1994-2005, Network Appliance, Inc. All rights
reserved.
Part No. 210-01108-A0
File: device11.htm
Last updated: Wed Apr 13 11:17:49 2005