There are three separate cases to consider when installing a CPU module. Choose one of the following three procedures, based on your system criteria:
To install the CPU module in a nonclustered system, complete the following steps.
| 1 |
Put on the antistatic wrist strap and grounding leash. |
|
| 2 |
Connect all cables to the CPU module before inserting the module into its CPU module bay. For more information, see Connecting your appliance to a network. |
|
| 3 |
From the back of your appliance, slide the module into the CPU module bay and push the cam mechanism levers into place. |
|
| 4 |
For FAS270 onlySet the terminate switch on the CPU module to the proper position. See Step 7 of the section Connecting a nonclustered FAS250 or FAS270. |
|
| 5 |
Reconnect the power to your appliance and turn on the power switch on both power supplies. See Connecting your system to a power source. |
|
| 6 |
If you installed a new CPU module with a new CompactFlash card, the card might not contain any data, in which case you need to boot your appliance from a remote image. See Netboot process for the FAS200 series. |
|
| 7 |
At the console screen, bring your system to the CFE (common firmware environment) prompt, or halt the system if it tries to autoboot Data ONTAP, by entering the following command: halt |
|
| 8 |
Run diagnostics on the new CPU module by entering the following command: boot_diags |
|
| 9 |
At the diagnostics prompt, run all tests by entering the following command: all Note |
|
| 10 |
Exit diagnostics by entering the following command: exit See the Diagnostics Guide at http://now.netapp.com for more information. |
|
| 11 |
Boot Data ONTAP by entering the following command: boot_ontap |
|
| 12 | ||
| 13 | ||
| 14 |
To see all disks and the old CPU module name, enter the following command: disk show -v |
|
| 15 | ||
| 16 |
Shut down the appliance by entering the following command at the console: halt |
|
| 17 |
Boot Data ONTAP by entering the following command: boot_ontap |
|
To install the CPU module in a clustered system where the partner node has not performed a takeover, complete the following steps.
| 1 |
Put on the antistatic wrist strap and grounding leash. |
|
| 2 |
Connect all cables to the CPU module before inserting the module into its CPU module bay. For more information, see Connecting your appliance to a network. |
|
| 3 |
From the back of your appliance, slide the module into the CPU module bay and push the cam mechanism levers into place. |
|
| 4 |
Set the terminate switch on the CPU module to the proper position. |
|
| 5 |
If power was removed, reconnect the power to your appliance and turn on the power switch on both power supplies. See Connecting your system to a power source. |
|
| 6 |
If you installed a new CPU module with a new CompactFlash card, the card might not contain any data, in which case you need to boot your appliance from a remote image. See Netboot process for the FAS200 series. |
|
| 7 | ||
| 8 |
Run diagnostics on the new CPU module by entering the following command: boot_diags |
|
| 9 |
At the diagnostics prompt, run all tests by entering the following command: all |
|
| 10 |
Exit diagnostics by entering the following command: exit See the Diagnostics Guide at http://now.netapp.com for more information. |
|
| 11 |
Boot Data ONTAP by entering the following command: boot_ontap |
|
| 12 | ||
| 13 | ||
| 14 |
To see all disks and the old CPU module name, enter the following command: |
|
| 15 | ||
| 16 |
Shut down the appliance by entering the following command at the console: halt |
|
| 17 |
Boot Data ONTAP by entering the following command: boot_ontap |
|
To install the CPU module in a clustered system where the partner node has performed a takeover, complete the following steps.
| 1 |
Put on the antistatic wrist strap and grounding leash. |
|
| 2 |
Connect all cables to the CPU module before inserting it into the module bay. For more information, see Connecting your appliance to a network. |
|
| 3 |
Set the terminate switch on the CPU module to the proper position. |
|
| 4 |
From the back of your appliance, slide the module into the module bay and push the cam mechanism levers into place. |
|
| 5 |
If you installed a new CPU module with a new CompactFlash card, the card might not contain any data, in which case you need to boot your appliance from a remote image. See Netboot process for the FAS200 series. |
|
| 6 |
Capture the output from the console. Be sure to write down the system ID number, as shown in bold in the following example. The output should look something like this:
Loading: 0xffffffff80001000/8500653 Entry at 0xffffffff80001000 Check that disks have been assigned ownership to this system (ID 84166052) using the 'disk show' and 'disk assign' commands from maintenance mode |
|
| 7 | ||
| 8 |
Reassign disk ownership for the new CPU module from the partner node with the new system ID, by entering the following commands at the takeover prompt: |
|
| 9 |
Enter the following command using the recorded system ID from Step 6, for example: The console screen should display something resembling the following:
node x(takeover)> priv set advanced
|
|
| 10 | ||
| 11 |
Verify disk ownership. Make sure that all disks that were supposed to be reassigned, were reassigned. |
|
| 12 |
The new CPU module should see the disk on the next reboot, accompanied by the following message: From the partner node, enter the following command: Note |
|