Monitoring the CPU module
LEDs on the FAS270/FAS270c CPU module
The CPU module has several LEDs. The LEDs indicate whether the CPU module, Fibre Channel ports, and network connections are functioning normally.
Location of LEDs on the CPU module
The following illustration shows the location of the Ethernet and Fibre Channel LEDs at the rear of the CPU module.
Interpreting Ethernet LEDs on a FAS270/FAS270c
Use the following table to interpret the Ethernet port LEDs on the FAS270/FAS270c CPU module.
Link LED (green)
|
Activity LED (amber)
|
State
|
|
Off
|
Off
|
Network connection is not present.
|
|
On
|
Off
|
Network connection is present but there is no data input or output occurring.
|
|
On
|
On/blinking
|
Network connection is present and data input and output is occurring.
|
Interpreting Fibre Channel LEDs on a FAS270/FAS270c
Use the following table to interpret the Fibre Channel LEDs on the FAS270/FAS270c CPU module.
Fault LED (amber)
|
Fibre Channel B LED (green)
|
Fibre Channel C LED (green)
|
State
|
Action
|
|
Off
|
On
|
On
|
Normal
|
None.
|
|
Off
|
Off
|
On
|
Loop B fault
|
Fibre Channel B loop is open and needs to be fixed.
|
|
Off
|
On
|
Off
|
Loop C fault
|
Fibre Channel C loop is open and needs to be fixed.
|
|
On
|
On
|
On
|
CPU module fault
|
Perform the following steps until the problem is resolved:
- Check the cables at the rear of the
system.
- Make sure that the 1 Gb/2 Gb
switches are set to 1 Gb.
- Check all terminate switches. Last
shelf in the loop must be set to On.
All other shelves must be set to Off.
- If Fibre Channel C port is unused,
install the Fibre Channel terminator
or ignore the Fibre Channel C LED.
It is alright for the LED to be off if
the port is not used.
- Run diagnostics to isolate the failure
and decide whether CPU module
replacement is necessary. See the
Diagnostics Guide for more
information.
- Replace the CPU module. See
Replacing the CPU module.
- Contact NetApp technical support.
|
|
On
|
Off
|
On
|
Loop B fault and module fault
|
|
On
|
On
|
Off
|
Loop C fault and module fault
|
LEDs on the FAS250 CPU module
The CPU module has two LEDs. The LEDs indicate whether the CPU module and the Fibre Channel port are functioning normally.
Location of LEDs on the FAS250 CPU module
The following illustration shows the location of the LEDs at the rear of the FAS250 CPU module.
Interpreting CPU module LEDs on a FAS250
Use the following table to interpret the FAS250 CPU module LEDs.
FC Status LED (green)
|
Fault LED (amber)
|
State
|
Action
|
|
On
|
Off
|
Normal
|
None.
|
|
Off
|
Off
|
Loop fault
|
Fibre Channel loop is open and needs to be fixed.
|
|
On
|
On
|
CPU module fault
|
Perform the following steps until the problem is resolved.
- Run diagnostics to isolate
the failure and decide if
CPU module replacement
is necessary. See the
Diagnostics Guide for
more information.
- Replace the CPU module.
See Replacing the CPU
module.
- Contact NetApp technical
support.
|
|
Off
|
On
|
Loop fault and module fault
|