To install the disk shelf using two-post mounting brackets, complete the following steps.
WARNING
You must install each disk shelf with either the two Telco brackets or the center-of-gravity brackets that came with the rack mounting hardware kit in your shipment package. Do not ear-mount the R150 into a Telco-type rack without Telco support brackets; the R150 disk shelf will collapse from the rack under its own weight.
| 1 | ||
| 2 | ||
|
Install the storage engine and disk shelves according to the recommended component arrangement; see Rules for arranging the components in the rack. | ||
|
Carefully replace the previous shelf in the rack with the newer shelf; see Replacing a disk shelf in a rack. | ||
| 3 |
Select two holes on each side of the rack for the installation. |
|
| 4 | ||
|
The following illustration shows an R150 disk shelf with a mid-mount bracket installed.
|
||
| ||
|
The following illustration shows the rear view of the rack mount kit being installed.
|
||
|
The following illustration shows an R150 disk shelf being attached using the rack mount kit.
|
||
| 5 |
Repeat the disk shelf installation for each disk shelf until five disk shelves are installed together from the bottom of the rack. |
|
| 6 |
Go to Installing an R150 storage engine for instructions about installing the storage engine. |
|
| 7 | ||
|
Go to Step 8 | ||
|
Repeat the disk shelf installations for the remaining four disk shelves above the storage engine. | ||
| 8 |
Go to Connecting an R150 System. |
|