Displaying information about HBAs

How to display HBA information  Top

The following table lists the commands available for displaying information about HBAs. The output varies depending on the FCP cfmode setting and the storage system model.

If you want to display...

Use this command...

Information for all adapters in the system, including firmware level, PCI bus width and clock speed, node name, cacheline size, Fibre Channel packet size, link data rate, SRAM parity, and various states

storage show adapter

All adapters (including HBAs, NICs, and switch port) configuration and status information

sysconfig [-v] [adapter] 

adapter is a numerical value only, for example, 5.

-v displays additional information about all adapters.

Disks, disk loops, and options configuration information that affects coredumps and takeover

sysconfig -c

FCP cfmode setting

fcp show cfmode

FCP Traffic information

sysstat -f

How long FCP has been running

uptime

Initiator HBA port address, port name, node name, and igroup name connected to target HBAs

fcp show initiator [-v] [adapter&portnumber]

-v displays the Fibre Channel host address of the initiator.

adapter&portnumber is the slot number with the port number, a or b; for example, 5a.

Service statistics

availtime

Target HBAs configuration information

fcp config

Target HBAs node name, port name, and link state

fcp show adapter [-p] [-v] 
[adapter&portnumber] 

-p displays information about adapters running on behalf of the partner node.

-v displays additional information about target adapters.

adapter&portnumber is the slot number with the port number, a or b; for example, 5a.

Target HBAs statistics

fcp stats [-z] [adapter&portnumber]

-z zeros the statistics.

adapter&portnumber is the slot number with the port number, a or b; for example, 5a.

Information about traffic from the B ports of the partner storage system

sysstat -b

WWNN (node name) of the target HBA

fcp nodename

Displaying information about all adapters  Top

To display information about all adapters installed in the storage system, complete the following step.

Step

Action

1

At the storage system, enter the following command to see information about all adapters.

sysconfig -v

Result

System configuration information and adapter information for each slot that is used is displayed on the screen. Look for Fibre Channel Target Host Adapter to get information about target HBAs.

Note
In the output, in the information about the Dual-channel QLogic HBA, the value 2312 does not specify the model number of the HBA; it refers to the device ID set by QLogic.

Note
The output varies according to storage system model. For example, if you have a FAS270, the target port is displayed as slot 0: Fibre Channel Target Host Adapter 0c.

Example

A partial display of information about a target HBA installed in slot 7 appears as follows:

slot 7: Fibre Channel Target Host Adapter 7a
          (Dual-channel, QLogic 2312 (2352) rev. 2, 64-bit, <ONLINE>)
          Firmware rev:   3.2.18
          Host Port Addr: 170900
          Cacheline size: 8
          SRAM parity:    Yes
          FC Nodename:    50:0a:09:80:86:87:a5:09 (500a09808687a509)
          FC Portname:    50:0a:09:83:86:87:a5:09 (500a09838687a509)
          Connection:     PTP, Fabric
  slot 7: Fibre Channel Target Host Adapter 7b
          (Dual-channel, QLogic 2312 (2352) rev. 2, 64-bit, <ONLINE>)
          Firmware rev:   3.2.18
          Host Port Addr: 171800
          Cacheline size: 8
          SRAM parity:    Yes
          FC Nodename:    50:0a:09:80:86:57:11:22 (500a098086571122)
          FC Portname:    50:0a:09:8c:86:57:11:22 (500a098c86571122)
          Connection:     PTP, Fabric

Displaying brief target HBA information  Top

To display configuration information about target HBAs, and to quickly detect whether they are active and online, complete the following step.

The output of the fcp config command depends on the storage system model and cfmode setting. For examples, see Chapter 8, Managing FCP in a clustered environment."

Step

Action

1

At the storage system, enter the following command.

fcp config

Sample output

7a:   ONLINE <ADAPTER UP>  PTP  Fabric
        host address 170900
        portname 50:0a:09:83:86:87:a5:09  nodename 50:0a:09:80:86:87:a5:09
        mediatype ptp  partner adapter 7a

 
7b:   ONLINE <ADAPTER UP>  PTP  Fabric
        host address 171800
        portname 50:0a:09:8c:86:57:11:22  nodename 50:0a:09:80:86:57:11:22
        mediatype ptp  partner adapter 7b

Sample output for FAS270

For the FAS270, the fcp config command displays the target virtual local, standby, and partner ports.

0c:   ONLINE <ADAPTER UP>  Loop  Fabric
        host address 0100da
        portname 50:0a:09:81:85:c4:45:88  nodename 50:0a:09:80:85:c4:45:88
        mediatype loop  partner adapter 0c
0c_0: ONLINE Local
        portname 50:0a:09:81:85:c4:45:88  nodename 50:0a:09:80:85:c4:45:88
        loopid 0x7 portid 0x0100da
0c_1: OFFLINED BY USER/SYSTEM Standby
        portname 50:0a:09:81:85:c4:45:91  nodename 50:0a:09:80:85:c4:45:91
        loopid 0x0 portid 0x000000
0c_2: ONLINE Partner
        portname 50:0a:09:89:85:c4:45:91  nodename 50:0a:09:80:85:c4:45:91
        loopid 0x9 portid 0x0100d6

Sample output for FAS3000:

The fcp config command displays information about the onboard ports connected to the SAN:

0c:   ONLINE <ADAPTER UP>  PTP  Fabric
        host address 010900
        portname 50:0a:09:81:86:f7:a8:42  nodename 50:0a:09:80:86:f7:a8:42
        mediatype ptp  partner adapter 0d

 
0d:   ONLINE <ADAPTER UP>  PTP  Fabric
        host address 010800
        portname 50:0a:09:8a:86:47:a8:32  nodename 50:0a:09:80:86:47:a8:32
        mediatype ptp  partner adapter 0c

Displaying detailed target HBA information  Top

To display the node name, port name, and link state of all target HBAs, complete the following step. Notice that the port name and node name are displayed with and without the separating colons. For Solaris hosts, you use the WWPN without separating colons when you map adapter port names (or these target WWPNs) to the host.

Step

Action

1

At the storage system, enter the following command:

fcp show adapter

Sample output for F8xx or FAS9xx series systems

The following sample output displays information for the HBA in slot 7:

Slot:                    7a
Description:             Fibre Channel Target Adapter 7a (Dual-channel, QLogic 2
312 (2352) rev. 2)
Adapter Type:            Local
Status:                  ONLINE
FC Nodename:             50:0a:09:80:86:87:a5:09 (500a09808687a509)
FC Portname:             50:0a:09:83:86:87:a5:09 (500a09838687a509)
Standby:                 No

 
Slot:                    7b
Description:             Fibre Channel Target Adapter 7b (Dual-channel, QLogic 2
312 (2352) rev. 2)
Adapter Type:            Partner
Status:                  ONLINE
FC Nodename:             50:0a:09:80:86:57:11:22 (500a098086571122)
FC Portname:             50:0a:09:8c:86:57:11:22 (500a098c86571122)
Standby:                 No

Note
In the display, the information about the Dual-channel QLogic HBA, the value 2312, does not specify the model number of the HBA; it refers to the device ID set by QLogic.

Note
For the FAS270, the fcp show adapter command displays the target virtual local (0c_0), standby (0c_1), and partner (0c_2) ports.

Displaying initiator HBA information  Top

To display the port name and igroup name of initiator HBAs connected to target HBAs, complete the following step.

Step

Action

1

At the storage system, enter the following command:

fcp show initiator

Result

The following output is displayed:

Initiators connected on adapter 7a:
Portname                  Group
10:00:00:00:c9:39:4d:82   sunhost_1
50:06:0b:00:00:11:35:62   hphost
10:00:00:00:c9:34:05:0c   sunhost_2
10:00:00:00:c9:2f:89:41   aixhost

 
Initiators connected on adapter 7b:
Portname                  Group
10:00:00:00:c9:2f:89:41   aixhost
10:00:00:00:c9:39:4d:82   sunhost_1
50:06:0b:00:00:11:35:62   hphost
10:00:00:00:c9:34:05:0c   sunhost_2

Displaying statistics  Top

To display information about the activity on target HBAs, complete the following step.

Step

Action

1
Enter the following command:
fcp stats -i interval [-c count] [-a | adapter]

-i interval is the interval, in seconds, at which the statistics are displayed.

-c count is the number of intervals. For example, the lun stats -i 10 -c 5 command displays statistics in ten-second intervals, for five intervals.

-a shows statistics for all adapters.

adapter is the slot and port number of a specific target HBA.

Example output

fcp stats -i 1
  r/s   w/s   o/s   ki/s   ko/s  asvc_t    qlen hba
    0     0     0      0      0    0.00    0.00 7a
  110   113     0   7104  12120    9.64    1.05 7a
  146    68     0   6240  13488   10.28    1.05 7a
  106    92     0   5856  10716   12.26    1.06 7a
  136   102     0   7696  13964    8.65    1.05 7a

Explanation of output

Each column displays the following information:

r/s--The number of SCSI read operations per second.

w/s--The number of SCSI write operations per second.

o/s--The number of other SCSI operations per second.

ki/s-- Kilobytes per second of received traffic

ko/s--Kilobytes per second send traffic.

asvc_t--Average time in milliseconds to process a request

qlen--The average number of outstanding requests pending.

hba--The HBA slot and port number.

Displaying FCP traffic information  Top

To display FCP traffic information (FCP ops/s, KB/s), complete the following step.

Step

Action

1

Enter the following command:

sysstat -f

Result

The following output is displayed:

CPU    NFS   CIFS    FCP      Net   kB/s     Disk kB/s       FCP  kB/s    Cache
                               in   out     read  write      in   out      age
 81%      0      0   6600       0     0   105874  56233   40148 232749       1
 78%      0      0   5750       0     0   110831  37875   36519 237349       1
 78%      0      0   5755       0     0   111789  37830   36152 236970       1
 80%      0      0   5732       0     0   111222  44512   35908 235412       1
 81%      0      0   7061       0     0   107742  49539   42651 232778       1
 78%      0      0   5770       0     0   110739  37901   35933 237980       1
 79%      0      0   5693       0     0   108322  47070   36231 234670       1
 79%      0      0   5725       0     0   108482  47161   36266 237828       1
 79%      0      0   6991       0     0   107032  39465   41792 233754       1
 80%      0      0   5945       0     0   110555  48778   36994 235568       1
 78%      0      0   5914       0     0   107562  43830   37396 235538       1

Explanation of FCP statistics

The following columns provide information about FCP statistics.

CPU--The percentage of the time that one or more CPUs were busy.

FCP--The number of FCP operations per second.

FCP KB/s--The number of kilobytes per second of incoming and outgoing FCP traffic.

Displaying information about traffic from the partner  Top

If you have a cluster and your system's cfmode setting is partner, mixed, or dual_fabric, you might want to obtain information about the amount of traffic coming to the system from its partner.

To display information about traffic from the partner (FCP ops/s, KB/s), complete the following step.

Step

Action

1

Enter the following command:

sysstat -b

Result

The following columns display information about partner traffic:

  • Partner--The number of partner operations per second
  • Partner KB/s--The number of kilobytes per second of incoming and outgoing partner partner traffic.

Displaying how long FCP has been running  Top

To display information about how long FCP has been running, complete the following step.

Step

Action

1

Enter the following command:

uptime

Result

The following output is displayed:

12:46am up 2 days, 8:59 102 NFS ops, 2609 CIFS ops, 0 HTTP ops, 0 DAFS ops, 
1933084 FCP ops, 0 iSCSI ops

Displaying FCP service statistics  Top

To display FCP service statistics, complete the following step.

Step

Action

1

Enter the following command:

availtime

Result

The following output is displayed:

Service statistics as of Mon Jul 1 00:28:37 GMT 2002
System (UP). First recorded (3894833) on Thu May 16 22:34:44 GMT 2002
        P   28, 230257, 170104, Mon Jun 10 08:31:39 GMT 2002
        U   24, 131888, 121180, Fri Jun  7 17:39:36 GMT 2002
NFS    (UP). First recorded (3894828) on Thu May 16 22:34:49 GMT 2002
        P   40, 231054, 170169, Mon June 10 08:32:44 GMT 2002
        U   36, 130363, 121261, Fri Jun   7 17:40:57 GMT 2002
FCP     P   19, 1417091, 1222127, Tue Jun 4 14:48:59 GMT 2002
        U   6, 139051, 121246, Fri Jun 7 17:40:42 GMT 2002

Displaying the HBA's WWNN  Top

To display the WWNN of a target HBA, complete the following step.

Step

Action

1

Enter the following command:

fcp nodename

Result


Fibre Channel nodename: 50:a9:80:00:02:00:8d:b2 (50a9800002008db2)

Library Table of Contents Index Previous Page (Alt-p) Next Page (Alt-n) Comments