Library Table of Contents Index Previous Page (Alt-p) Next Page (Alt-n) Comments

Overview of dual_fabric mode

How target ports provide access to LUNs  Top

The dual_fabric mode is supported on FAS270c clusters only. It is not supported on other systems.

The FAS270c cluster consists of two storage systems integrated into a disk shelf. Each storage system has two Fibre Channel ports. The orange-labeled port operates as a Fibre Channel target port after you license the FCP service and reboot the storage system. The blue-labeled port connects to the internal disks, enabling you to connect additional disk shelves to an FAS270c cluster. The Fibre Channel target port of each FAS270c storage system in the cluster supports three virtual ports:

Configurations with the FAS270c require that multipathing software be installed on the hosts.

The following figure shows the recommended production configuration, in which a multi-attached host accesses a FAS270c cluster.

What happens during a failover  Top

The virtual ports enable the FAS270c cluster, which has only one physical target FCP port per node, to support traffic for both nodes in the cluster. For example, if Switch 1 fails, the multipathing software on the host uses HBA 2 and Switch 2 to access the partner virtual port on Node B. The partner virtual port forwards the requests to Node A. When the cluster is in a takeover state (Node B takes over for Node A), Node B uses the partner virtual port to directly serve data for LUNs on Node A.

How Data ONTAP displays target port information  Top

State of Fibre Channel Port 1

When the FAS270c port labeled Fibre Channel 1 operates as a SAN target, the sysconfig -v command shows this port as a Fibre Channel Target Host Adapter installed in slot 0. The following example shows sysconfig -v output for a FAS270c in SAN target mode.

fas270> sysconfig
        NetApp Release 7.1: Mon June 25 02:20:04 PDT 2005
        System ID: 0084165669 (filer_1); partner ID: 0084165671 (filer_2)
        System Serial Number: 379589 (filer_1)
        slot 0: System Board
                Processors:         2
                Processor revision: B2
                Processor type:     1250
                Memory Size:        1022 MB
        slot 0: FC Host Adapter 0b 
                14 Disks:            952.0GB
                1 shelf with EFH
        slot 0: Fibre Channel Target Host Adapter 0c
        slot 0: SB1250-Gigabit Dual Ethernet Controller
                e0a MAC Address:    00:a0:98:00:d5:90 (100tx-fd-up)
                e0b MAC Address:    00:a0:98:00:d5:91 (auto-unknown-cfg_down)
        slot 0: NetApp ATA/IDE Adapter 0a (0x00000000000001f0)
                0a.0                 122MB

Target virtual ports

FCP commands display three virtual ports for the one FAS270c physical target FCP port. For example, the fcp show adapter command shows the target FCP port as an adapter in slot 0c. The local virtual port is 0c_0, the standby virtual port is 0c_1, and the partner virtual port is 0c_2.

The following output example shows how the fcp config command displays virtual ports when the storage system is in dual_fabric mode and the cluster is in normal operation.

FAS270> fcp config
0c:   ONLINE <ADAPTER UP>  Loop  Fabric
        host address 0100da
        portname 50:0a:09:81:85:c4:45:91  nodename 50:0a:09:80:85:c4:45:91
        mediatype loop  partner adapter 0c
0c_0: ONLINE Local
        portname 50:0a:09:81:85:c4:45:91  nodename 50:0a:09:80:85:c4:45:91
        loopid 0x7 portid 0x0100da
0c_1: OFFLINE Standby
        portname 50:0a:09:81:85:c4:45:88  nodename 50:0a:09:80:85:c4:45:88
        loopid 0x0 portid 0x000000
0c_2: ONLINE Partner
        portname 50:0a:09:89:85:c4:45:88  nodename 50:0a:09:80:85:c4:45:88
        loopid 0x9 portid 0x0100d6