Understanding disks

About disks  Top

Disks have several characteristics, which are either attributes determined by the manufacturer or attributes that are supported by Data ONTAP. Data ONTAP manages disks based on the following characteristics:

Disk type  Top

Data ONTAP supports the following disk types, depending on the specific storage system, the disk shelves, and the I/O modules installed in the system:

The following table shows what disk type is supported by which storage system, depending on the disk shelf and I/O module installed.

NetApp Storage System

Disk Shelf Supported

I/O Module

Disk Type

F87

Internal disk shelf

Not applicable.

SCSI

F800 series

Fibre Channel StorageShelf FC7, FC8, FC9

Not applicable.

FC

DS14
DS14mk2 FC

LRC, ESH, ESH2

FAS250

DS14mk2 FC (not expandable)

Not applicable.

FC

FAS270

DS14mk2 FC

LRC, ESH2

FC

FAS920
FAS940

Fibre Channel StorageShelf FC7, FC8, FC9

Not applicable.

FC

DS14, DS14mk2 FC

LRC, ESH, ESH2

FC

FAS960

Fibre Channel StorageShelf FC7, FC8, FC9

Not applicable.

FC

DS14, DS14mk2 FC

LRC, ESH, ESH2

FC

DS14mk2 AT

AT-FCX

ATA

FAS980

Fibre Channel StorageShelf FC9

Not applicable.

FC

DS14, DS14mk2 FC

LRC, ESH, ESH2

FC

FAS3020
FAS3050
FAS3070

DS14, DS14mk2 FC

LRC, ESH, ESH2

FC

DS14mk2 AT

AT-FCX

ATA

R100

R1XX disk shelf

Not applicable.

ATA

R150

R1XX disk shelf

Not applicable.

ATA

DS14mk2 AT

AT-FC

ATA

R200

DS14mk2 AT

AT-FC

ATA

For more information about disk support and capacity, see the System Configuration Guide on the NetApp on the Web (NOW) site at http://now.netapp.com/. When you access the System Configuration Guide, select the Data ONTAP version and storage system to find current information about all aspects of disk and disk shelf support and storage capacity.

Disk capacity  Top

When you add a new disk, Data ONTAP reduces the amount of space on that disk available for user data by rounding down. This maintains compatibility across disks from various manufacturers. The available disk space listed by informational commands such as sysconfig is, therefore, less for each disk than its rated capacity (which you use if you specify disk size when creating an aggregate). The available disk space on a disk is rounded down as shown in the following table.

Disk

Right-sized Capacity

Available blocks

FC/SCSI disks

4-GB disks

4 GB

8,192,000

9-GB disks

8.6 GB

17,612,800

18-GB disks

17 GB

34,816,000

35-GB disks
(block checksum disks)

34 GB

69,632,000

36-GB disks
(zoned checksum disks)

34.5 GB

70,656,000

72-GB disks

68 GB

139,264,000

144-GB disks

136 GB

278,528,000

288-GB disks

272 GB

557,056,000

ATA/SATA disks

160-GB disks
(available on R100 storage systems)

136 GB

278,258,000

250-GB disks
(available on R150, R200, FAS900, and FAS3000 storage systems)

212 GB

434,176,000

320-GB disks
(available on R200, FAS900, and FAS3000 storage systems)

274 GB

561,971,200

Disk speed  Top

Disk speed is measured in revolutions per minute (RPM) and directly impacts input/output operations per second (IOPS) per drive as well as response time. Data ONTAP supports the following speeds for FC and ATA disk drives:

For more information about supported disk speeds, see the System Configuration Guide. For information about optimizing performance with 15K RPM FC disk drives, see the Technical Report (TR3285) on the NOWTM site at http://now.netapp.com/.

It is best to create homogenous aggregates with the same disk speed rather than mix drives with different speeds. For example, do not use10K and 15K FC disk drives in the same aggregate. If you plan to upgrade 10K FC disk drives to 15K FC disk drives, use the following process as a guideline:

  1. Add enough 15K FC drives to create homogenous aggregates and FlexVol volumes (or traditional volumes) to store existing data.
  2. Copy the existing data in the FlexVol volumes or traditional volumes from the 10K drives to the 15K drives.
  3. Replace all existing 10K drives in the spares pool with 15K drives.

Disk checksum format  Top

All new NetApp storage systems use block checksum disks (BCDs), which have a disk format of 520 bytes per sector. If you have an older storage system, it might have zoned checksum disks (ZCDs), which have a disk format of 512 bytes per sector. When you run the setup command, Data ONTAP uses the disk checksum type to determine the checksum type of aggregates that you create. For more information about checksum types, see How Data ONTAP enforces checksum type rules.

Disk addressing  Top

Disk addresses are represented in the following format:

HA.disk_id

HA refers to the host adapter (HA) number, which is the slot number on the storage system where the host adapter is attached, as shown in the following examples:

disk_id is a protocol-specific identifier for attached disks. For Fibre Channel-Arbitrated Loop (FC-AL), the disk_id is an integer from 0 to 126. However, Data ONTAP only uses integers from 16 to 125. For SCSI, the disk_id is an integer from 0 to 15.

The disk_id corresponds to the disk shelf number and the bay in which the disk is installed, based on the disk shelf type. This results in a disk drive addressing map, which is typically included in the hardware guide for the disk shelf. The lowest disk_id is always in the far right bay of the first disk shelf. The next higher disk_id is in the next bay to the left, and so on. The following tables show examples of disk drive addressing maps for these disk shelves:

Fibre Channel disk drive addressing maps

The following table illustrates the shelf layout for the DS14 disk shelf. Note that the SES drives are in bay 0 and bay 1, and that the drive bay numbers begin with 16, on shelf ID 1.

DS14
Shelf ID

Bay

13

12

11

10

9

8

7

6

5

4

3

2

1

0

SES drives

7

125

124

123

122

121

120

119

118

117

116

115

114

113

112

6

109

108

107

106

105

104

103

102

101

100

99

98

97

96

5

93

92

91

90

89

88

87

86

85

84

83

82

81

80

4

77

76

75

74

73

72

71

70

69

68

67

66

65

64

3

61

60

59

58

57

56

55

54

53

52

51

50

49

48

2

45

44

43

42

41

40

39

38

37

36

35

34

33

32

1

29

28

27

26

25

24

23

22

21

20

19

18

17

16

The following table illustrates the shelf layout for the FC7, FC8, and FC9 disk shelves. Note that the SES drives are in bay 3 and bay 4, and that the drive bay numbers begin with 0, on shelf ID 0.

FC7, FC8, FC9
Shelf ID

Bay

6

5

4

3

2

1

0

SES drives

7

62

61

60

59

58

57

56

6

54

53

52

51

50

49

48

5

46

45

44

43

42

41

40

4

38

37

36

35

34

33

32

3

30

29

28

27

26

25

24

2

22

21

20

19

18

17

16

1

14

13

12

11

10

9

8

0

6

5

4

3

2

1

0

NearStore disk drive addressing map

The following table illustrates the shelf layout for the R100 and R150 disk shelves. Note that bays 4 through 7 are not shown.

R100, R150
Shelf ID

Bay

15

14

13

12

11

10

9

8

3

2

1

0

1

15

14

13

12

11

10

9

8

3

2

1

0

RAID group disk type  Top

The RAID group disk type determines how the disk will be used in the RAID group. A disk cannot be used until it is configured as one of the following RAID group disk types and assigned to a RAID group.