You can change the level of RAID protection configured for an aggregate. When you change an aggregate's RAID level, Data ONTAP reconfigures all the existing RAID groups to the new level and applies the new level to all subsequently created RAID groups in that aggregate.
Before you change an aggregate's RAID protection from RAID4 to RAID-DP, you need to ensure that hot spare disks of sufficient number and size are available. During the conversion, Data ONTAP adds an additional disk to each existing RAID group from the storage system's hot spare disk pool and assigns the new disk the dParity disk function for the RAID-DP group. In addition, the aggregate's raidsize option is changed to RAID-DP as the default on this storage system. The raidsize option also controls the size of new RAID groups that might be created in the aggregate.
To change an existing aggregate's RAID protection from RAID4 to RAID-DP, complete the following steps.
| 1 |
Determine the number of RAID groups and the size of their parity disks in the aggregate in question by entering the following command. aggr status aggr_name -r |
| 2 |
Enter the following command to make sure that a hot spare disk exists on the storage system for each RAID group listed for the aggregate in question, and make sure that these hot spare disks match the size and checksum type of the existing parity disks in those RAID groups. aggr status -s If necessary, add hot spare disks of the appropriate number of appropriate number, size, and checksum type to the storage system. See Prerequisites for adding new disks. |
| 3 |
aggr options aggr_name raidtype raid_dp aggr_name is the aggregate whose RAID level (raidtype) you are changing. ExampleThe following command changes the RAID level of the aggregate this aggr to RAID-DP: aggr options thisaggr raidtype raid_dp For backward compatibility, you can enter the following command: vol options vol_name raidtype raid_dp |
When you change the RAID protection level of an existing aggregate from RAID4 to RAID-DP, the following associated RAID group size changes take place:
If hot spare disks available on the storage system are of insufficient number or size to support the RAID level conversion, Data ONTAP issues a warning before executing the command to set the RAID level to RAID-DP (either aggr options aggr_name raidtype raid_dp or vol options vol_name raidtype raid_dp).
If you continue the operation, RAID-DP protection is implemented on the aggregate in question, but some of its RAID groups for which no second parity disk was available remain degraded. In this case, the protection offered is no improvement over RAID4, and no hot spare disks are available in case of disk failure since all were reassigned as dParity disk.
Note
After the aggr options aggr_name raidtype raid_dp operation is complete, you can manually change the raidsize option through the aggr options aggr_name raidsize command. See Changing the maximum size of RAID groups.
For backward compatibility, you can also use the following commands for traditional volumes:
vol options vol_name raidtype raid_dp operation
vol options vol_name raidsize command
While it is possible to change an aggregate from RAID-DP to RAID4, there is a restriction, as described in the following note.
Note
You cannot change an aggregate from RAID-DP to RAID4 if the aggregate contains a RAID group larger than the maximum allowed for RAID4.
To change an existing aggregate's RAID protection from RAID-DP to RAID4, complete the following step.
The RAID group size determines the size of any new RAID groups created in an aggregate. When you change the RAID protection of an existing aggregate from RAID-DP to RAID4, Data ONTAP automatically carries out the following associated RAID group size changes:
Note
For storage systems that support ATA disks, the restriction about not being able to change an aggregate from RAID-DP to RAID4 if the aggregate contains a RAID group larger than the maximum allowed for RAID4 also applies to traditional volumes.
After the aggr options aggr_name raidtype raid_dp operation is complete, you can manually change the raidsize option through the aggr options aggr_name raidsize command. See Changing the maximum size of RAID groups.
For backward compatibility, you can also use the following commands for traditional volumes:
vol options vol_name raidtype raid_dp
vol options vol_name raidsize
To verify the RAID level of an aggregate, complete the following step.
| 1 |
aggr status aggr_name aggr options aggr_name For backward compatibility, you can also enter the following command: vol options vol_name |