Creating mirrored aggregates and traditional volumes
Two ways to create mirrored aggregates or traditional volumes
You can create a mirrored aggregate or traditional volume in the following ways:
How Data ONTAP selects disks
Regardless of which way you create a mirrored aggregate or traditional volume, when you create it or add disks to it, Data ONTAP determines what disks to use. Data ONTAP uses the following policies when selecting disks for mirrored aggregate or traditional volumes:
Disk selection policies if you select disks
Data ONTAP allows you to select disks when creating mirrored aggregate or traditional volumes or adding disks to them. You need to follow the same disk selection policies that Data ONTAP follows when selecting disks for mirrored aggregate or traditional volumes. See the previous section, How Data ONTAP selects disks.
See Creating a mirrored aggregate or traditional volume and Adding a plex for information about creating mirrored aggregate or traditional volumes with disks you select.
Data ONTAP names plexes
Regardless of how a mirrored aggregate or traditional volume is created, Data ONTAP names the plexes of the mirrored aggregate or traditional volume. For more information about the plex naming convention, see What mirrored aggregates and traditional volumes are.
Viewing plex and disk pools
Viewing the disks in a plex or the spare disks in a disk pool is useful for adding disks to a plex or for understanding which plex is using which disk pool. To view plexes and disk pools, complete the following step.
Step
|
Action
|
|
1
|
Enter one of the following commands:
sysconfig -r
or
aggr status -r
or
vol status -r
|
Example
In this example, the aggr status -r command is used to view the disks in plexes and spare disks in disk pools:
system1> aggr status -r
Aggregate vol0 (online, raid4) (block checksums)
Plex /vol0/plex0 (online, normal, active, pool1)
RAID group /vol0/plex0/rg0 (normal)
RAID Disk Device HA SHELF BAY CHAN Pool Type RPM Used (MB/blks) Ph)
--------- ------ ------------- ---- ---- ---- ----- -------------- ---
parity 9a.16 9a 1 0 FC:A 1 FCAL 10000 34000/69632000 34
data 9a.17 9a 1 1 FC:A 1 FCAL 10000 600/1228800 76
data 9a.20 9a 1 4 FC:A 1 FCAL 10000 34000/69632000 34
Aggregate GreG (online, raid4) (block checksums)
Plex /GreG/plex0 (online, normal, active, pool1)
RAID group /GreG/plex0/rg0 (normal)
RAID Disk Device HA SHELF BAY CHAN Pool Type RPM Used (MB/blks) Ph)
--------- ------ ------------- ---- ---- ---- ----- -------------- ---
parity 9a.18 9a 1 2 FC:A 1 FCAL 10000 34000/69632000 34
data 9a.19 9a 1 3 FC:A 1 FCAL 10000 34000/69632000 34
Pool1 spare disks
RAID Disk Device HA SHELF BAY CHAN Pool Type RPM Used (MB/blks) Ph)
--------- ------ ------------- ---- ---- ---- ----- -------------- ---
Spare disks for block or zoned checksum traditional volumes or aggregates
spare 9a.24 9a 1 8 FC:A 1 FCAL 10000 34000/69632000 34
spare 9a.29 9a 1 13 FC:A 1 FCAL 10000 34000/69632000 34
Pool0 spare disks (empty)
Partner disks
RAID Disk Device HA SHELF BAY CHAN Pool Type RPM Used (MB/blks) Ph)
--------- ------ ------------- ---- ---- ---- ----- -------------- ---
partner 9b.25 9b 1 9 FC:B 1 FCAL 10000 0/0 34
partner 9b.16 9b 1 0 FC:B 1 FCAL 10000 0/0 34
partner 9b.17 9b 1 1 FC:B 1 FCAL 10000 0/0 34
partner 9b.21 9b 1 5 FC:B 1 FCAL 10000 0/0 34
partner 9b.18 9b 1 2 FC:B 1 FCAL 10000 0/0 34
partner 9b.22 9b 1 6 FC:B 1 FCAL 10000 0/0 34
tpubs-cf1>
|
Example
In this example, the vol status -r command is used to view the disks in plexes and spare disks in disk pools:
system1> vol status -r
Volume vol0 (online, raid4) (block checksums)
Plex /vol0/plex0 (online, normal, active, pool1)
RAID group /vol0/plex0/rg0 (normal)
|
RAID Disk Device HA SHELF BAY CHAN Pool Type RPM Used (MB/blks) Ph)
--------- ------ ------------- ---- ---- ---- ----- -------------- ---
parity 9a.16 9a 1 0 FC:A 1 FCAL 10000 34000/69632000 34
data 9a.17 9a 1 1 FC:A 1 FCAL 10000 600/1228800 76
data 9a.20 9a 1 4 FC:A 1 FCAL 10000 34000/69632000 34
|
Aggregate aggrz (online, raid4) (block checksums)
Plex /aggrz/plex0 (online, normal, active, pool1)
RAID group /aggrz/plex0/rg0 (normal)
|
RAID Disk Device HA SHELF BAY CHAN Pool Type RPM Used (MB/blks) Ph)
--------- ------ ------------- ---- ---- ---- ----- -------------- ---
parity 9a.25 9a 1 9 FC:A 1 FCAL 10000 34000/69632000 34
data 9a.26 9a 1 10 FC:A 1 FCAL 10000 34000/69632000 34
data 9a.27 9a 1 11 FC:A 1 FCAL 10000 34000/69632000 34
data 9a.28 9a 1 12 FC:A 1 FCAL 10000 34000/69632000 34
|
Pool1 spare disks
RAID Disk Device HA SHELF BAY CHAN Pool Type RPM Used (MB/blks) Ph)
--------- ------ ------------- ---- ---- ---- ----- -------------- ---
Spare disks for block or zoned checksum traditional volumes or aggregates
spare 9a.24 9a 1 8 FC:A 1 FCAL 10000 34000/69632000 34
spare 9a.29 9a 1 13 FC:A 1 FCAL 10000 34000/69632000 34
|
Pool0 spare disks (empty)
|
Partner disks
RAID Disk Device HA SHELF BAY CHAN Pool Type RPM Used (MB/blks) Ph)
--------- ------ ------------- ---- ---- ---- ----- -------------- ---
partner 9b.25 9b 1 9 FC:B 1 FCAL 10000 0/0 34
partner 9b.16 9b 1 0 FC:B 1 FCAL 10000 0/0 34
partner 9b.17 9b 1 1 FC:B 1 FCAL 10000 0/0 34
partner 9b.21 9b 1 5 FC:B 1 FCAL 10000 0/0 34
partner 9b.18 9b 1 2 FC:B 1 FCAL 10000 0/0 34
partner 9b.22 9b 1 6 FC:B 1 FCAL 10000 0/0 34
partner 9b.23 9b 1 7 FC:B 1 FCAL 10000 0/0 34
|
For detailed information
The following sections discuss the ways you can create mirrored aggregate or traditional volumes:
Copyright © 1994-2005, Network Appliance, Inc. All rights
reserved.
Part No. 210-01081_B0
File: syncmir4.htm
Last updated: 01-Dec-2005 16:36:26