You use the environment command to display information about the storage system environment. The exact types of information displayed depend on the command options.
For more information about the environment command, see the na_environment(1) man page.
The environment command displays the following types of information about the storage system environment:
You can query information about the following items:
Data ONTAP runs the environment command under the following conditions:
You run this command manually to monitor the storage system subsystems, especially when you suspect a problem and when reporting abnormal conditions to technical support.
The environment status command with no options displays all storage system environment information.
The environment status shelf command displays the shelf environmental status for all shelves. The environment status shelf adapter command displays shelf information for shelves attached to a specific adapter.
The environment chassis command displays the environmental status of all chassis components.
The environment chassis list-sensors command displays detailed information from all chassis sensors.
You can add UPS devices to be monitored, enable or disable monitoring of UPS devices, or display the status of UPS devices. The ups status command displays the status of all UPS devices.
To specifying a UPS device to be monitored by the storage system's environmental monitoring software, complete the following step.
| 1 |
ups add [-c community] IP_address Use -c community if you want to specify the community for the UPS device. IP_address is the IP address of the UPS device. |
To enable or disable monitoring of one or more UPS devices, complete the following step.