Before initiating the nondisruptive upgrade procedure, verify that you have completed any prerequisite procedures described in Preparing for the upgrade. All CompactFlash-based systems that satisfy these prerequisites can use the nondisruptive upgrade procedure.
To download Data ONTAP to clustered storage systems for a nondisruptive upgrade to Data ONTAP 7.1 from the 7.0 release family, complete the following steps.
| 1 |
At the console of each storage system, enter the following command to copy the executables to the boot blocks of the storage system's hard disks: download ResultThe download command provides an acknowledgment similar to the following: Tue Jun 19 10:03:22 GMT [download.request:notice]: Operator requested download initiated download: Downloading boot device......... download: Downloading disks: opening Data ONTAP 7.1 .......................done download: boot blocks successfully copied to disk(s) Then a message similar to the following appears: Tues Jun 19 10:11:51 GMT [download.requestDone:notice]: Operator requested download completed Note |
|
| 2 |
At the console of each storage system, enter the following command to verify that clustering is enabled: cf status ResultThe cf status command output should be similar to the following: Cluster enabled, filerA is up. If it is not, enter the following command to enable clustering: cf enable Then verify that clustering is re-enabled by entering the cf status command. |
|
| 3 |
At the console of each storage system, enter the following commands to compare the installed version of system firmware with the version on the CompactFlash card: sysconfig -a version -b ResultThe sysconfig command output contains an entry similar to the following: Firmware release: 4.3_i1 The version command output contains an entry similar to the following: 1:/x86/firmware/xfiler/firmware.img: Firmware 4.3.1_i2 If the version of the newly loaded firmware displayed by the version command is
|
|
| 4 | ||
|
Go to Step 5. | ||
cifs terminate -t nn where nn is a notification period (in minutes) appropriate for your clients. After that period of time, proceed to Step 5. | ||
| 5 |
At the console of system B, enter the following command: cf takeover ResultThis command causes system A to shut down gracefully and leaves system B in takeover mode. Note |
|
| 6 | ||
|
Go to Step 13. | ||
|
Go to Step 7. | ||
| 7 |
To display the boot prompt (CFE or ok, depending on your storage system) at the system A console, complete one of the following procedures: |
|
| 8 |
At the boot prompt, enter the following command: bye |
|
| 9 |
During the memory test, press Del to interrupt the boot process. Note ResultThe console displays the following messages: Skipping auto-boot Complete Startup aborted |
|
| 10 |
update-flash Result |
|
| 11 |
ResultThe system updates the firmware, displays several status messages, and displays the boot prompt. Note |
|
| 12 |
Enter the following command to reboot the system using the new firmware and software: bye |
|
| 13 |
When the Waiting for giveback message appears on the console of system A, enter the following command at the console of system B: cf giveback -f ResultThis command causes system A to reboot with the new system configuration--a Data ONTAP version and any system firmware and hardware changes--and resume normal operation as a cluster partner. Note |
|
| 14 | ||
|
Go to Step 15. | ||
cifs terminate -t nn where nn is a notification period (in minutes) appropriate for your clients. After that period of time, proceed to Step 15. | ||
| 15 |
At the console of system A, enter the following command: cf takeover -n ResultYou see output similar to the following: Waiting for partner to be cleanly shutdown using the 'halt' command. |
|
| 16 |
At the console of system B, enter the following command: halt ResultThis command causes system B to shut down cleanly, flushing file-system information in memory to disk. Note |
|
| 17 | ||
|
Go to Step 23. | ||
|
Go to Step 18. | ||
| 18 |
To display the boot prompt (CFE or ok, depending on your storage system) at the system B console, complete one of the following procedures: |
|
| 19 |
At the boot prompt, enter the following command: bye |
|
| 20 |
During the memory test, press Del to interrupt the boot process. Note ResultThe console displays the following messages: Skipping auto-boot Complete Startup aborted |
|
| 21 |
update-flash Result |
|
| 22 |
ResultThe system updates the firmware, displays several status messages, and displays the boot prompt. Note |
|
| 23 |
At the console of system B, enter the following command to reboot the system using the new system firmware (if it was installed) and software: bye |
|
| 24 |
When the Waiting for giveback message appears on the console of system B, enter the following command at the console of system A: cf giveback -f ResultThis command causes system B to reboot with the new system configuration--a Data ONTAP version and any system firmware and hardware changes--and resume normal operation as a cluster partner. When the reboot completes, the two cluster nodes are running the same Data ONTAP version. |
|
| 25 |
As needed, perform the procedures described in Concluding the upgrade. |
|
Copyright © 1994-2005, Network Appliance, Inc. All rights
reserved.
Part No. 210-01083_B0
File: 4ug_sw11.htm
Last updated: 16-Dec-2005 18:19:14