Downloading Data ONTAP to single systems and rebooting

Selecting a single system upgrade process  Top

To upgrade your single system, follow the instructions in the following sections based on your storage system model:

Downloading Data ONTAP and system firmware on an FAS200 series or FAS3000 series storage system  Top

The FAS200 series and FAS3000 series storage systems come with a CompactFlash card that you use when downloading firmware and system software.

Before initiating this download procedure, verify that you have completed any prerequisite procedures described in Preparing for the upgrade.

To download the Data ONTAP software and, if necessary, upgrade the firmware on one of these storage systems, complete the following steps at the storage system console.

Step

Action

1

Enter the following command to copy the kernel and firmware data files to the CompactFlash card:

download 

Result

The download command provides a status message similar to the following:

download: Depending on system load, it may take many
download: minutes to complete this operation.  Until it 
download: finishes, you will not be able to use the 
download: console. You can cancel this operation by 
download: hitting Ctrl-C in the next 6 seconds.

 
Tue Jul 15 10:03:22 GMT [download.request:notice]: 
Operator requested download initiated
download: Downloading boot device.........
...............Mon Apr 21 15:30:24 PDT [nbns_timer:info]: All CIFS name registrations complete for local server....
download: Downloading boot device (Service Area)

Then the following storage system message appears:

Tues Jul 15 10:11:51 GMT [download.requestDone:notice]: 
Operator requested download complete
2

Enter the following command to shut down the storage system:

halt

Result

After the storage system shuts down, the CFE firmware prompt appears.

Note
For more information about the Common Firmware Environment (CFE) boot environment and commands, see the System Administration Guide.

3

If a firmware upgrade...

Then...

Is needed on your storage system

Go to Step 4.

Is not needed on your storage system

Go to Step 6.

4

At the CFE prompt, enter the following command:

update_flash

Result

The update_flash command provides an acknowledgement similar to the following.

Reading flash0a: Done. 493328 bytes read

 
** DO NOT TURN OFF YOUR MACHINE UNTIL THE FLASH UPDATE 
COMPLETES!! **

 
Programming...done. 493328 bytes written
Reading 
fatfs://ide0.0/MIPS/firmware/FAS250/firmware.img: Done. 
493392 bytes read
Flash image is 493328 bytes, flags 00000002, CRC DE227E0D

 
** DO NOT TURN OFF YOUR MACHINE UNTIL THE FLASH UPDATE 
COMPLETES!! **

 
Programming...done. 493328 bytes written
5

Enter y to continue.

Result

The system updates the firmware, displays several status messages, and displays the CFE prompt.

6

At the CFE prompt, enter the following command to reboot the system using the new software and, if applicable, the new firmware:

bye

Downloading Data ONTAP and system firmware on an F825 or F880 storage system, or a FAS900 or NearStore series storage system  Top

The F825 and F880 storage systems, FAS900 series storage systems, and R100, R150, and R200 NearStore systems use a CompactFlash card for firmware and system software downloads.

Before initiating this download procedure, verify that you have completed any prerequisite procedures described in Preparing for the upgrade.

To download the Data ONTAP software and, if necessary, upgrade the firmware on one of these storage systems, complete the following steps at the storage system console.

Step

Action

1

Enter the following command to copy the executables to the boot blocks of the storage system's hard disks:

download 

Result

The download command provides a status message similar to the following:

Tue Jun 19 10:03:22 GMT [download.request:notice]: 
Operator requested download initiated
download: Downloading boot device.........
download: Downloading disks: opening Data ONTAP 7.1 .......................done
download: boot blocks successfully copied to disk(s)

Then a message similar to the following appears:

Tues Jun 19 10:11:51 GMT [download.requestDone:notice]: 
Operator requested download completed
2

Enter the following command to shut down the storage system:

halt

Result

After the storage system shuts down, the ok prompt appears.

3

Enter the following command to reboot the system:

bye

Result

The storage system begins the boot process.

4

If a firmware upgrade...

Then...

Is needed on your storage system

When the memory test begins, press Del to interrupt the boot process.

Note
If you are using a terminal emulation package and it does not support Del, use Ctrl-Bksp instead.

Result

The console displays the following messages:

Skipping auto-boot 
Complete
Startup aborted

Then the console displays the ok prompt.

Continue to Step 5.

Is not needed on your storage system

You are done.

5

Enter the following command:

update-flash

Result

The system prompts you to continue.

6

Enter y to continue.

Result

The system updates the firmware, displays several status messages, and displays the ok prompt.

Note
If you installed a system firmware upgrade, you might have to run the set-defaults command from the firmware ok prompt before rebooting your storage system. For more information, see Considerations concerning system firmware upgrades.

7

Enter the following command to reboot the system using the new firmware and software:

bye

Downloading Data ONTAP on F87, F810, F820, and F840 storage systems  Top

Before initiating this download procedure, verify that you have completed any prerequisite procedures described in Preparing for the upgrade.

To download Data ONTAP to the disks and reboot F87, F810, F820, and F840 storage systems, complete the following steps.

Step

Action

1

At the storage system console, enter the following command to copy the executables to the boot blocks of the storage system's hard disks:

download

Result

The download command provides an acknowledgment similar to the following:

Tue Jun 19 10:03:22 GMT [download.request:notice]: 
Operator requested download initiated
download: Downloading disks: opening Data ONTAP 7.1 
.......................done
download: boot blocks successfully copied to disk(s)

Then the following storage system prompt appears:

Tues Jun 19 10:11:51 GMT [download.requestDone:notice]: 
Operator requested download completed
2

At the storage system console, reboot the storage system with the following command:

reboot
3

As needed, perform the procedures described in Concluding the upgrade.