Reverting to the Data ONTAP 7.0 release family

Issues you must resolve when reverting  Top

The following sections discuss upgrade issues that you must resolve when reverting to a Data ONTAP 7.0 family release:

SnapVault relationships to SnapLock volumes must be removed before reverting  Top

Before reverting to a version of Data ONTAP earlier than 7.1, SnapVault relationships to SnapLock volumes must be removed. This includes

For more information about SnapVault and SnapLock technologies, see the Data Protection Online Backup and Recovery Guide.

Secondary SnapVault configurations must be removed from NearStore systems before reverting  Top

If you revert a NearStore system that is being used as a SnapVault secondary storage system to a Data ONTAP release earlier than 7.1, you must remove SnapVault configuration from all qtrees on all volumes. This includes

To do so, complete the following steps at the NearStore system command line.

Step

Action

1

Identify qtrees under SnapVault control by entering the following command:

snapvault status

2

For each qtree identified in the previous, enter the following command:

snapvault stop -f /vol/my_volume/my_qtree

3

If you are managing NearStore systems with VERITAS NetBackup, enter the following commands for each volume containing NetBackup backups:

snapvault stop -f /vol/my_volume/.nbu_image_data
snap delete -a -f
my_volume

For more information about managing secondary SnapVault relationships on NearStore systems, see the Data Protection Online Backup and Recovery Guide.

Reversion cannot take place during I2P initialization  Top

When you upgrade to Data ONTAP 7.1, inode to pathname (I2P) information is written to each existing volume. You cannot revert to an earlier release while the system is being scanned to initialize I2P. Before proceeding with the reversion, you must do one of the following:

To abort the I2P scan, complete the following step.

Step

Action

1

Enter the following command:

vol options no_i2p on

Result

Inode to pathname translation is disabled immediately and the reversion can proceed.

Note
Because any I2P information is removed during a reversion, reverting to an earlier release can take several hours, depending on the number of inodes and volumes on your system, and whether the I2P scan completed.