By default, a vFiler unit can use the protocols that are licensed for the hosting storage system. For example, if the hosting storage system is licensed for CIFS and NFS, the vFiler units created can also use the CIFS and NFS protocols. You can select those protocols that you allow or disallow on the vFiler units.
The maximum number of FTP connections to a vFiler unit is determined by the ftpd.max_connections option set on the hosting storage system. The value set for this option is shared among the vFiler units on a storage system on a first-come, first-served basis.
You can select the protocols that you allow on the vFiler units using the vfiler allow command. You can select the protocols that you disallow on the vFiler units using the vfiler disallow command. vFiler units support the following protocols:
To allow CIFS, NFS, FTP, or HTTP on a vFiler unit, each of the allowed protocols must have an active license on the hosting storage system.
If a CIFS, NFS, iSCSI, FTP, or HTTP protocol is running and you disallow it, the protocol continues to run until the storage system reboots, but packets destined for the vFiler unit are ignored.
After iSCSI is disallowed on a vFiler unit, the following conditions apply on that vFiler unit:
After FTP is disallowed on a vFiler unit, no new FTP connections are allowed to the vFiler unit; however, transfers that started before FTP was disallowed will finish.
After HTTP is disallowed on a vFiler unit, no new HTTP connections are allowed on the vFiler unit. Each new request receives a "503 HTTP server is disabled" message. Any existing connections remain alive.
Although the Data ONTAP rsh.enable option value (On or Off) determines whether the RSH server is enabled or disabled on a storage system, disallowing rsh on a vFiler unit is independent of the value for that option. That is, a vFiler unit can be configured to disallow rsh even when the rsh.enable option is set to On.
Note
You must have the rsh.enable option set to On and the vFiler unit configured to allow rsh on a vFiler unit.
To allow or disallow protocols for a vFiler unit, complete the following steps.
| 1 | ||
|
Go to Step 2. | ||
|
Go to Step 3. | ||
| 2 |
To allow a protocol, enter the following command: vfiler allow vfilertemplate proto=protocol ... protocol is nfs, cifs, iscsi, rsh, ftp, or http. ExampleThe following example allows the NFS and rsh protocols on the vFiler unit named vFiler1: vfiler allow vfiler1 proto=nfs proto=rsh |
|
| 3 |
To disallow a protocol, enter the following command: vfiler disallow vfilertemplate proto=protocol ... protocol is nfs, cifs, iscsi, rsh, ftp, or http. ExampleThe following command disallows the NFS and rsh protocols on the vFiler unit named vFiler1: |
|