To reactivate the original vFiler unit on the original storage system using SnapMirror commands, perform the following steps.
| 1 |
Boot the original storage system and interrupt the boot process by pressing the Del or Esc key while the memory self-test is in progress. Note |
|
| 2 |
At the OK prompt, set the no-vfiler-ips? variable as follows: setenv no-vfiler-ips? true This ensures that the storage system does not try to bind IP addresses already being used by the disaster-recovery vFiler unit. When the storage system boots, the original vFiler unit starts running, but it does not accept any read or write requests because its interfaces are unconfigured. |
|
| 3 |
Resynchronize the mirrored volumes and qtrees. For each volume and qtree owned by the original vFiler unit, enter the following command on the original storage system (the one you are trying to activate): snapmirror resync -S disaster_recovery_filer:/pathname original_filer:/pathname Examplesnapmirror resync -S drfiler:/vol/vfiler1/qtree1 prfiler:/vol/vfiler1/qtree TroubleshootingIf the snapmirror resync command fails, telling you that there are no matching Snapshot copies, you might have accidentally deleted the Snapshot copies that SnapMirror depends on. In this case, you need to initialize SnapMirror using the snapmirror initialize command (see the na_snapmirror man page for details). Then continue with the next step of this procedure, but skip Step 7 when you get there. |
|
| 4 |
Find out if the snapmirror.access option on the disaster-recovery storage system is set to legacy. Enter the following command on the disaster-recovery storage system: options snapmirror |
|
| 5 | ||
|
The options snapmirror command returns snapmirror.access legacy |
Edit the file /etc/snapmirror.allow and add the host name of the original storage system if it is not already there. | |
|
The options snapmirror command returns a list of host names, and the name of the original storage system is not in the list |
Use the options snapmirror command to add the host name of the original storage system. Exampleoptions snapmirror.access host=fridge,toaster,prfiler | |
| 6 |
Run setup on the disaster-recovery vFiler unit and unconfigure its IP addresses. |
|
| 7 |
Update the data on the original vFiler unit. For each volume and qtree owned by the original vFiler unit, enter the following command on the original storage system: snapmirror update -S disaster_recovery_filer:/pathname original_filer:/pathname Examplesnapmirror update -S drfiler:/vol/vfiler1/qtree1 prfiler:/vol/vfiler1/qtree1 |
|
| 8 |
Stop SnapMirror transfers to the disaster-recovery vFiler unit. For each volume and qtree owned by the original vFiler unit, enter the following command on the original storage system: snapmirror quiesce pathname Examplesnapmirror quiesce /vol/vfiler1/qtree1 Note |
|
| 9 |
Check that all the paths are quiesced by entering the following command: snapmirror status The status column in the output should show each path as Quiesced. |
|
| 10 |
Break the SnapMirror relationship. For each volume and qtree owned by the original vFiler unit, enter the following command on the original storage system: snapmirror break pathname Examplesnapmirror break /vol/vfiler1/qtree1 |
|
| 11 |
On the original vFiler, run setup to configure the vFiler unit's IP addresses and configure the NIS and DNS servers. |
|
| 12 |
If the storage units that have been copied contain iSCSI LUNs, check that the iSCSI configuration on the original vFiler unit is intact and still makes sense. You might need to remap the LUNs and re-create initiator groups (igroups). |
|
| 13 |
If the storage units that have been copied contain iSCSI LUNs, bring the LUNs back online on the original vFiler unit. |
|
| 14 |
Stop the disaster-recovery vFiler unit. On the disaster-recovery storage system, enter the following command: vfiler stop vfilername vfilername is the name of the disaster-recovery vFiler unit. You are done reactivating the original storage system. To ensure that you have a disaster recovery vFiler unit available for the vFiler unit on the reactivated original storage system, go to the next step. |
|
| 15 |
Resynchronize the disaster-recovery vFiler unit. From the disaster-recovery storage system, perform the procedure Resynchronizing the original vFiler unit. |
|