To reactivate the original vFiler unit on the original storage system, perform the following steps.
| 1 |
Boot the original storage system and interrupt the boot process by pressing the Del or Esc key while the memory self-test is in progress. Note |
|
| 2 |
At the OK prompt, set the no-vfiler-ips? variable as follows: setenv no-vfiler-ips? true This ensures that the storage system does not try to bind IP addresses already being used by the disaster-recovery vFiler unit. |
|
| 3 | ||
| 4 |
Destroy the original vFiler unit. Enter the following command on the original storage system: vfiler destroy vfilername |
|
| 5 |
Follow the procedure for Creating a replacement vFiler unit on the original storage system or its replacement. |
|
Follow these steps to create a replacement vFiler unit on the original (production) storage system or its replacement. If you are reactivating the vFiler unit on the original storage system, make sure you perform this procedure only after completing the preparatory steps in Reactivating the vFiler unit using the vFiler dr commands.
| 1 |
Stop the disaster-recovery vFiler unit by using the vfiler stop command. |
|
| 2 |
Prepare for the new vFiler unit on the original (or its replacement) storage system: Perform the preparation steps in Preparing the destination storage system. |
|
| 3 |
Update the data on the original storage system: For each volume and qtree owned by the new vFiler unit, enter the following commands on the original (or its replacement) storage system: snapmirror break name snapmirror resync -S disaster_recovery_filer:name production_filer:name disaster_recovery_filer is the name of the disaster recovery storage system production_filer is the name of the original storage system name is the volume name or path name of the qtree Example 1For volume vol1, enter the following commands: snapmirror break drfiler:vol1 snapmirror resync -S drfiler:vol1 prfiler:vol1 Example 2For qtree qtree1, enter the following commands: snapmirror break drfiler:/vol/vol2/qtree1 snapmirror resync -S drfiler:/vol/vol2/qtree1 prfiler:/vol/vol2/qtree1 |
|
| 4 |
Create the new vFiler unit on the original (or its replacement) storage system, following directions under Creating the vFiler unit. The original vFiler unit is now reactivated on the original storage system or its replacement. |
|
| 5 |
Reinstate the disaster-recovery vFiler unit on the disaster-recovery storage system. |
|
|
On the disaster-recovery storage system, enter the following command: vfiler dr resync [-l authinfo] [-a alt-remote, alt- local] [-s] original_vfilername@original_filer For details of the vfiler dr resync command, see Step 2 of Resynchronizing the original vFiler unit. | ||
| ||
Copyright © 1994-2005, Network Appliance, Inc. All rights
reserved.
Part No. 210-01078-B0
File: disast12.htm
Last updated: 08-Dec-2005 13:31:53