You should read this section and perform the instructions provided in this section if you want to migrate a vFiler unit by copying data from a physical (source) storage system to another physical (destination) storage system. You might want to copy data from one storage system to another to maintain a backup copy of the data so that if the primary disks fail or the data on them becomes inaccessible, you can use the backup copy to restore services to clients.
Before you begin the migration, make sure the following are true:
Note
If the storage systems are not on the same subnet, you need to run setup (and cifs setup if necessary) on the new vFiler unit after the migration to configure authority servers as specified on your worksheet. See If you have moved the vFiler unit to a different subnet or Windows domain for details.
If you migrate a vFiler unit to another storage system on the same subnet, you see the following effects on clients:
Although an iSCSI host is briefly disconnected from the source vFiler unit, an initiator hides this brief disruption from applications accessing the LUNs. To the applications, access continues without interruption.
For information on moving a vFiler unit to a storage system on a different subnet, see If you have moved the vFiler unit to a different subnet or Windows domain.
Attention
The procedure that follows destroys the original vFiler unit after replicating it on the destination storage system. If you want to leave the original vFiler unit intact and create a backup copy of it for disaster-recovery purposes, use the procedures listed under How to create, activate, or delete a disaster-recovery vFiler unit instead.
To migrate the storage system by copying data from one vfiler unit to another, perform the following steps.
Note
The following procedure uses the vfiler migrate command to migrate the vFiler unit by copying data. For more information about the vfiler migrate command and various options available for the command, see the na_vfiler man page.
| 1 |
Qualify and prepare the destination storage system. Perform the checks listed in Preparing the destination storage system. |
|
| 2 |
On the destination storage system, enter the following command: vfiler migrate start source_vfiler@source_filer Note |
|
| 3 |
Respond to the login prompt with a valid administrative ID and password for the source storage system. |
|
| 4 |
Respond to the IP address and binding prompts, using the addresses you entered on the "new interface" lines on the worksheet. |
|
| 5 |
Monitor the progress of the migration with the following command: vfiler migrate status source_vfiler@source_filer Note |
|
| 6 |
When the status command reports that SnapMirror has replicated all the storage units of the source vFiler unit, complete the migration by entering the following command: vfiler migrate complete source_vfiler@source_filer Note vfiler migrate cancel source_vfiler@source_filer This destroys the destination vFiler unit and removes the SnapMirror and other migration-related configuration information from the source vFiler unit. Note |
|
| 7 |
If you copied quota information into the destination storage system's /etc/quotas file (see Step 8 of Preparing the destination storage system earlier in this chapter) activate the quotas on that storage system. For each volume you are activating quotas on, use the following command: quota on volume_name |
|
| 8 |
Make adjustments on the clients. You will need to remount qtrees, but volume-level mounts should be intact. |
|
| 9 |
If you have moved the vFiler unit to a different subnet, follow the steps in If you have moved the vFiler unit to a different subnet or Windows domain. |
|
| 10 |
If the vFiler unit's storage units contain iSCSI LUNS, reconfigure iSCSI authentication. |
|
The vfiler migrate start command does the following:
The vfiler migrate complete command does the following:
If you have moved the vFiler unit to a different subnet, you might need to configure the network servers and make adjustments on the clients. If you have moved the vFiler unit to a different Windows domain, you might also need to modify data-file security attributes.
Perform the following steps on the destination vFiler unit.
Copyright © 1994-2005, Network Appliance, Inc. All rights
reserved.
Part No. 210-01078-B0
File: disast15.htm
Last updated: 08-Dec-2005 13:31:53